Display Settings Menu:
The contrast is adjusted between 00 an 15 in this menu.
Holiday Lock Menu:
In this menu, the set programs are deactivated for a time period which is entered by the user. 4 different
holiday times can be entered by the user. The user must enter and approve the start date(as dd:mm), the
start time(as HH:mm), the finish date(as dd:mm) and the finish time(as HH:mm) of a holiday. After the
approval, “
HOLDAY X-FULL
” will appear on the screen. For an occupied holiday setting, “
EDIT
” ve “
DELETE
”
options are available. If “
EDIT
” is selected for a holiday lock, the existing settings for that holiday lock can
be observed and edited. If “
DELETE
” is selected for a holiday lock, the settings for that holiday lock is
deleted.
The changes are saved to the memory when the “
SAVE
” query is confirmed by the user while returning to
the monitoring menu. See Program Example 3.
Manual Mode Menu:
The setting for leaving the manual mode after the device is set in manual mode
is done in this menu. There are 3 parameters. The user can leave the manual mode with the DOWN button
regardless of what parameter he chooses in this menu.
Disabled Parameter(
DISABL
):
When this parameter is selected; after the manual mode is enabled with the UP/DOWN buttons for any
of the outputs, it must be disabled again with the UP/DOWN buttons.
Program
Parameter(
NEXT-P
)
:
When this parameter is selected; after the relay/relays is/are activated or deactivated by a program in the
program flow, the manual mode for the relay/relays will be disabled.
Timer Parameter(
TIMER
)
:
When this parameter is selected; the user will be prompted to enter the time as HH:mm. The device will
start to count back from the entered time when the manual mode is enabled for the relay/relays. If the time
is entered as 23:59, the manual mode will be disabled after 23 hours and 59 minutes.If the time is entered
as 00:01, the manual mode will be disabled after 1 minute. There is a special case if the time is entered
as 00:00. With this entered time, the manual mode will be disabled after 1 minute too.
Password Settings Menu:
The activation and changing of a password is done in this menu. The factory default value for the password
is “0000”. The 4 digit password is prompted before entering this menu. If the password is activated, it isn’t
prompted again before entering this menu since the password was entered before entering the main
programming menu.
CONTRAS
08
MO
CONTRAS
08
CONTRAS
05
CONTRAS
05
MO
Can be set
between
00~15
C1:
C2: