background image

1

2

NOTICE

Enterasys Networks and its licensors reserve the right to make changes in specifications and other 
information contained in this document without prior notice. The reader should in all cases consult 
Enterasys Networks to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY 
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER 
(INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS 
MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS 
AND ITS LICENSORS HAVE BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE 
POSSIBILITY OF SUCH DAMAGES.

Enterasys Networks, Inc.
35 Industrial Way
Rochester, NH 03866-5005

Enterasys Networks, Inc. is a subsidiary of Cabletron Systems, Inc.

 2001 by Enterasys Networks, Inc.

All Rights Reserved

Printed in the United States of America

Order Number: 9033687-01 June 2001

X-Pedition and Enterasys are registered trademarks of Enterasys Networks or its licensors. All other 
product names mentioned in this manual may be trademarks or registered trademarks of their respective 
companies.

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment uses, 
generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s 
manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause interference in which case the user will be required to correct the 
interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the 
party responsible for compliance could void the user’s authority to operate the equipment.

INDUSTRY CANADA NOTICE

This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus 
set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté 
par le ministère des Communications du Canada.

VCCI NOTICE

This is a class A product based on the standard of the Voluntary Control Council for Interference by 
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio 
disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

CLASS A ITE NOTICE

WARNING: This is a class A product. In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures. 

DECLARATION OF CONFORMITY

Application of Council Directive(s):

89/336/EEC
73/23/EEC

Manufacturer’s Name:

Enterasys Networks, Inc.

Manufacturer’s Address:

35 Industrial Way
PO Box 5005
Rochester, NH 03867

European Representative Name:

Mr. Jim Sims

European Representative Address:

Enterasys Networks Ltd.
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England

Conformance to Directive(s)/

Product Standards:

EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 55024
EN 60950
EN 60825

Equipment Type/Environment:

Networking Equipment, for use in a
Commercial or Light Industrial Environment.

Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above 
directives.

AGENCY STANDARDS

Safety

Meets the requirements of UL 1950, CSA C22.  No. 950, EN 60950, IEC 950, 
73/23/EEC, and EN 60825.

Electromagnetic Compatibility

Compliant with the requirements of FCC Part 15, CSA C108.8, EN 55022, EN 61000-3-2, 
EN 61000-3-3, VCCI V-3, EN 55024, 89/336/EEC, and AS/NZS 3548

Protocols

RFC 2225 Classical IP over ATM (CLIP) 

RFCs/MIBs

RFC 1483, Multiprotocol Encapsulation over ATM Adaptation Layer 5; RFC 1595, 
SONET MIB; RFC 1695, ATM MIB; RFC 2495, DS1 MIB; RFC 2496, DS3 MIB; 
RFC 2225, Classical IP over ATM

SPECIFICATIONS

The SSR-ATM29-02 is a modular, high-performance OC-3c ATM interface for 
the X-Pedition 8000 and 8600. The module is optimized to provide an ATM 
uplink to an ATM backbone, and supports two modular slots, each of which 
accepts T1/E1, T3/E3 and OC-3c (single mode and multimode fiber, as well as 
unshielded twisted pair) interface.

Ports

Depending on the APHY used, 1 or 2.

Interface

XP 8000/8600 2-port base module

Physical Dimensions

Size: 27.94 cm H x 19.68 W x 3.94 D (11.00 in. H x 7.75 W x 1.55 D) 
Weight: 1.4 kg (3.0 lb.)

Power Consumption

30-35 Watts (depending on which APHY is installed)

Temperature

Operating: 41° to 104°F (5° to 40°C) 
Storage: -22° to 164°F (-30° to 73°C)

Humidity

5% to 90% (non-condensing)

LEDs

SSR-ATM29-02

The fully integrated design of the X-Pedition family increases the value of the 
product line by providing a seamless solution to support the industry’s most 
complete range of technology and media options. This scalable framework 
ensures full cross-platform compatibility and allows for the smoothest possible 
migration as customers’ technology and interface requirements evolve.

The combination of the X-Pedition and the SSR-ATM29-02 OC-3c module 
provide a complete solution for both the service provider and enterprise 
markets. Interconnecting IP networks over an ATM backbone is done by many 
service provider and enterprise customers. The OC-3c module provides the 
vital link between the network’s switch-router solutions and the ATM-based 
solution in the WAN. Each PVC on the module can be configured as a routed 
IP interface, and the ATM backbone can provide connectivity from one routed 
backbone to another.

Options Available

This module operates with the following APHYs (you may purchase them 
separately from the module) connected to the outside world. For information 
about these APHYs, consult the Enterasys Networks web site.

Table 1

LED Indicators

LED

Condition

Status

Hotswap 
LEDs (2)

Yellow (Top) 

Unit is not functioning, cannot hotswap.

Green (Bottom) 

Unit is operational.

Port 1 Traffic 
LEDs (2)

Tx Green 
(Top)

Indicates when the transceiver receives packets.

Rx Green (Bottom)

Indicates when the transceiver receives flow-
control packets.

Port 2 Traffic 
LEDs (2)

Tx Green 
(Top)

Indicates when the transceiver transmits packets.

Rx Green (Bottom)

Indicates when the transceiver transmits flow-
control packets.

PHY (Top)

Green

The PHY is operating properly and a link is 
established.

Yellow

The PHY is inactive due to media errors.

Blinking Green

The PHY was disabled by management.

Off

No connection.

Lightning 
(Bottom)

Yellow 

The diagnostics have detected a fault.

Blinking Green

The PHY port has been redirected elsewhere.

Off

Unit is operating properly.

XP-APHY-67
XP-APHY-77
XP-APHY-92

XP-APHY-21
XP-APHY-29IR
XP-APHY-22

XP-APHY-82 

ELECTRICAL HAZARD: The APHY-82 and APHY-92 are designed 
for intra-building use only. A properly approved CSU must be used for 
attachment to outside telecommunications lines (T1/E1).

WARNING: The APHY-21, APHY-29, and APHY-29LR use Class 1 
Lasers. Do not use optical instruments to view laser output. The use 
of optical instruments to view laser output increases eye hazard.