set rmon alarm status
13-10
RMON Configuration
Defaults
interval
‐
3600
seconds
type
‐
absolute
startup
‐
rising
rthresh
‐
0
fthresh
‐
0
revent
‐
0
fevent
‐
0
owner
‐
monitor
Mode
Switch
command,
read
‐
write.
Example
This
example
shows
how
to
configure
a
rising
RMON
alarm.
This
entry
will
conduct
monitoring
of
the
delta
between
samples
every
30
seconds:
C2(rw)->set rmon alarm properties 3 interval 30 object
1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager
set rmon alarm status
Use
this
command
to
enable
an
RMON
alarm
entry.
An
alarm
is
a
notification
that
a
statistical
sample
of
a
monitored
variable
has
crossed
a
configured
threshold.
Syntax
set rmon alarm status
index enable
Parameters
Defaults
None.
Mode
Switch
command,
read
‐
write.
Usage
An
RMON
alarm
entry
can
be
created
using
this
command,
configured
using
the
set
rmon
alarm
properties
command
then
enabled
using
this
command.
An
RMON
alarm
entry
can
be
created
and
configured
at
the
same
time
by
specifying
an
unused
index
with
the
set
rmon
alarm
properties
command.
index
Specifies
an
index
number
for
this
entry.
Maximum
number
or
entries
is
50
.
Maximum
value
is
65535.
enable
Enables
this
alarm
entry.
Содержание SecureStack C2
Страница 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Страница 2: ......
Страница 28: ...xxvi ...
Страница 106: ...set ssl 3 52 Basic Configuration ...
Страница 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Страница 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Страница 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Страница 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Страница 454: ...no license advanced 15 6 Preparing for Router Mode ...