Enterasys ER16-GTX32-04 Скачать руководство пользователя страница 1

1

2

NOTICE

Enterasys Networks and its licensors reserve the right to make changes in specifications and other 
information contained in this document without prior notice. The reader should in all cases consult 
Enterasys Networks to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY 
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER 
(INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS 
MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS 
AND ITS LICENSORS HAVE BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE 
POSSIBILITY OF SUCH DAMAGES.

Enterasys Networks, Inc.
35 Industrial Way
Rochester, NH 03866-5005

 2001 by Enterasys Networks, Inc.

All Rights Reserved
Printed in the United States of America

Order Number: 9033770 November 2001

X-Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors. All 
other product names mentioned in this manual may be trademarks or registered trademarks of their 
respective companies.

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment uses, 
generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s 
manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause interference in which case the user will be required to correct the 
interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the 
party responsible for compliance could void the user’s authority to operate the equipment.

INDUSTRY CANADA NOTICE

This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus 
set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté 
par le ministère des Communications du Canada.

VCCI NOTICE

This is a class A product based on the standard of the Voluntary Control Council for Interference by 
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio 
disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

CLASS A ITE NOTICE

WARNING: This is a class A product. In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures. 

DECLARATION OF CONFORMITY

Application of Council Directive(s):

89/336/EEC
73/23/EEC

Manufacturer’s Name:

Enterasys Networks, Inc.

Manufacturer’s Address:

35 Industrial Way
PO Box 5005
Rochester, NH 03867

European Representative Address:

Enterasys Networks Ltd.
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England

Conformance to Directive(s)/

Product Standards:

EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 55024
EN 60950
EN 60825

Equipment Type/Environment:

Networking Equipment, for use in a
Commercial or Light Industrial Environment.

Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above 
directives.

AGENCY STANDARDS

Safety

Meets the requirements of UL 1950, CSA 22.2 No. 950, 73/23/EEC, EN 60825, 
EN 60950, and IEC 950.

Electromagnetic Compatibility

Compliant with the requirements of FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022, 
EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS 3548, and VCCI V-3.

ER16-GTX32-04

The ER16-GTX32-04 is a copper-based 1000Base-T Gigabit Ethernet module for the 
Enterasys X-Pedition platform. The ER16-GTX32-04 provides four ports of 1000Base-T 
switched and routed connectivity through Category 5 RJ45 connectors and is ideal for 
high-speed collapsed backbones and server-farm connections. The ER16-GTX32-04 
delivers full-function Layer-2, Layer-3, and Layer-4 switching and routing.

SPECIFICATIONS

Ports

4 1000Base-T Ports

ASIC Type

T-Series

Network Interface

RJ-45 100m Cat5 UTP Cabling per ANSI/TIA/EIA-568-A

Number of Flows/Routes

Layer-2 Entries = 512,000 (memory size = 64 MB)
Layer-3 Entries = 512,000 (memory size = 32 MB)

Switch Method

Address-based and Flow-based.

Physical Dimensions

Size: 45.16 cm H x 2.54 W x 35.24 D (17.78 in. H x 1 W x 13.88 D)
Weight 2.3 kg (5.0 lbs)

Power Consumption

BTU/hr = 362.6

AC Volt Amps = 107.31

Temperature

Operating: 41° to 104° F (5° to 40° C) 
Storage: -22° to 164° F (-30° to 73° C) 

Humidity

15% to 90% (non-condensing)

CONNECTIVITY GUIDELINES

LEDs

Options Available

The ER16-GTX32-04 provides switching and routing on hardware, thereby eliminating 
the performance bottleneck caused by a single processor. The module supports application 
switching (i.e., Network Address Translation, Server Load Balancing, Per-Flow Rate 
Limiting, Access Control Lists, and full RMON/RMON 2) and extra features like the 
Local Hardware Routing Table, Port Rate Limiting, Aggregate Rate Limiting, and Jumbo 
Frames that are essential for Application Service Providers, Multi-Dwelling Unit (MDU) 
Service Providers, and Large Enterprise Networks.

The ER16-GTX32-04 offers ten times the bandwidth available through the existing 
Category 5 infrastructure and interoperates with all existing X-Pedition Router modules. 
This allows network managers to leverage their existing cabling infrastructure and 
equipment without an extensive upgrade. 

INSTALLING THE MODULE

Handling the Module

To prevent electrostatic damage, observe the following guidelines:

Do not remove the module from its packaging until you are ready to install it.

Do not touch any of the module’s pins, connectors or components.

Hold the module only by its edges or front panel.

Wear an anti-static wristband connected to a suitable earth ground whenever handling 
the module.

Store or transport this module only in appropriate anti-static packaging.

Table 1

Recommended Cable Types and Specifications

Cable

Type

Max. Length

Connector

100Base-TX

Cat. 5 100-ohm UTP

100 m (328 ft)

RJ-45

Table 2

LED Indicators

LED

Condition

Status

Online

On (Green)

The module is online and ready to receive, process, and 
send packets (if configured to do so).

Offline

On (Amber)

The module is offline (powered down) and ready to 
hotswap.

Per-Port 
Transmit

Green

The port transmitted a packet. The OCMAC controls 
this LED.

Orange

The port transmitted a flow-control packet. The 
OCMAC controls this LED.

Per-Port 
Receive

Green

The port received a packet. The OCMAC controls this 
LED.

Orange

The port received a flow-control packet. The OCMAC 
controls this LED.

Per-Port Link

Green

The port hardware detected a cable plugged into the 
port and established a good link.

Off

No link exists from the port.

Per-Port 
Quality

Green

Autonegotiation completed successfully and the phy is 
attempting to establish a link. This LED remains green 
while the link operates with good signal-to-noise ratio.

Fast blink

Low signal-to-noise ratio, close to data errors.

Slow blink

Receive bit errors detected.

Off

Autonegotiation is in progress or the phy cannot receive 
packet data.

ELECTRICAL HAZARD: Only qualified personnel should perform 
installation procedures.

CAUTION: The ER16-GTX32-04 is designed for slots 1-7 or 9-16 
only, and is easily damaged by electrostatic discharge.