background image

1

2

3

4

Notice

Enterasys Networks reserves the right to make changes in 
specifications and other information contained in this document and its 
web site without prior notice. The reader should in all cases consult 
Enterasys Networks to determine whether any such changes have been 
made.

The hardware, firmware, or software described in this document is 
subject to change without notice.

IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR 
ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL 
DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO 
LOST PROFITS) ARISING OUT OF OR RELATED TO THIS 
DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN 
THEM, EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF, 
KNEW OF, OR SHOULD HAVE KNOWN OF, THE POSSIBILITY OF 
SUCH DAMAGES.

Enterasys Networks, Inc.
50 Minuteman Road
Andover, MA 01810

 2004 Enterasys Networks, Inc. All rights reserved.

Part Number: 9033945 February 2004

ENTERASYS, ENTERASYS NETWORKS, NETSIGHT, ROAMABOUT, 
and any logos associated therewith, are trademarks or registered 
trademarks of Enterasys Networks, Inc. in the United States and other 
countries.

All other product names mentioned in this manual may be trademarks 
or registered trademarks of their respective companies.

FCC Communication Commission 
Interference Statement

This equipment has been tested and found to comply with the limits for 
a Class B digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the 
following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth 
for an uncontrolled environment. This equipment should be installed 
and operated with minimum distance 20cm between the radiator & 
your body.

If the RBT3K-AG or RBT3K-AG-G device is going to be operated in 
5.15 ~ 5.25GHz frequency range, then it is restricted in indoor 
environment only.

This transmitter must not be co-located or operating in conjunction 
with any other antenna or transmitter.

Enterasys Networks declares that the RBT3K-1G, RBT3K-AG, and 
RBT3K-AG-G (RoamAbout Access Point 3000) are limited in the 2.4 
GHz band on channel 1-11 by specified firmware controlled in USA.

Industry Canada (Canada) - Class B 
Computing Device:

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme 
NMB-003 du Canada.

Europe - EC Declaration of Conformity

This device complies with Low Voltage Directive 73/23/EEC and EMC 
Directive 89/336/EEC.

VCCI Notice

This is a Class B product based on the standard of the Voluntary 
Control Council for Interference from Information Technology 
Equipment (VCCI). If this is used near a radio or television receiver in a 
domestic environment, it may cause radio interference. Install and use 
the equipment according to the instruction manual.

Specifications

For the complete Access Point 3000 (part number RBT3K-1G, 
RBT3K-AG, and RBT3K-AG-G) specifications, refer to the 

RoamAbout 

Access Point 3000 Hardware Installation and Configuration Guide

.

Physical Size

21.83 x 13.73 x 3.27 cm (8.60 x 5.40 x 1.29 in.)

Weight

0.80 kg (1.76 lbs)

Power Supply

Input: 100-240 AC, 50-60 Hz

Output: 5.1 VDC, 3A

Power consumption: 13.2 watts

802.1af compliant: input voltage 48 VDC, 0.27A, 12.96 watts

Temperature

Operating: 0 to 55 

°

C (32 to 131 

°

F)

Storage: 0 to 70 

°

C (32 to 158 

°

F)

Humidity

15% to 95% (non-condensing)

EMC Compliance (Class B)

FCC Class B (US)

ICES-003 (Canada)

VCCI (Japan)

RCR STD-33A

EN55024, EN55022

CISPR 22-96

Radio Signal Certification

Safety

CSA/NTRL (CSA 22.2 No. 950 & UL 60950)
EN60950 (T

Ü

V/GS), IEC60950 (CB) 

LVD/EN60950
Plenum Rated UL 2043

Standards

IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.11a, b, g

Access Point 3000 Overview

The Enterasys Networks Wireless Access Point 3000 is an IEEE 
802.11a/b/g (RBT3K-AG & RBT3K-AG-G), or an IEEE 802.11b/g 
only (RBT3K-1G), access point that provides transparent, 
wireless high-speed data communications between the wired 
LAN and fixed, portable or mobile devices equipped with an 
802.11a, 802.11b or 802.11g wireless adapter. 

This solution offers fast, reliable wireless connectivity with 
considerable cost savings over wired LANs (which include 
long-term maintenance overhead for cabling). Using 802.11a, 
802.11b, and 802.11g technology, this access point can easily 
replace a 10 Mbps Ethernet connection and provide seamless 
integration into a 10/100 Mbps Ethernet LAN.

In addition, the access point offers full network management 
capabilities through an easy to configure web interface, and a 
command line interface for initial configuration and 
troubleshooting.

Installation

Please read the Regulatory, FCC, and specification information 
before you install the RoamAbout Access Point 3000.

To install the RoamAbout Access Point 3000, perform the 
following steps:

1. Select a site. Choose a proper place for the access point. The 

best location is at the center of your wireless coverage area, 
within line of sight of all wireless devices. Try to place the 
access point in a position that can best cover its Basic Service 
Set. Normally, the higher you place the access point, the 
better the performance.

FCC CAUTION: 

Changes or modifications made to 

this device which are not expressly approved by the 
party responsible for compliance could void the user’s 
authority to operate the equipment.

RBT3K-AG & RBT3K-AG-G

2.4 GHz & 5 GHz

RBT3K-1G

2.4 GHz Only

FCC part 15.247 (2.4 GHz)

FCC part 15.247 (2.4 GHz)

FCC part 15 15.407(b)

RSS-210 (Canada)

RSS-210 (Canada)

EN 300.328-1 V1.3.1

EN 300.328-1 V1.3.1

EN 300.328-2 V1.2.1

EN 300.328-2 V1.2.1

EN 301 489-01: V.1.3.1

EN 301 489-17: V.1.2.1

EN 301 893: V.1.2.1

MPT RCR std.33 (D33 1~13 Chan-
nel, T66 Channel 14)

MPT RCR std.33 (D33 1~13 Channel, 
T66 Channel 14)

Electrical Hazard: Only qualified personnel should 
perform installation procedures.

Caution: Ensure that you wear the ESD (Electrical Static 
Discharge) strap during the installation.