background image

 

9031994-01

 

SmartSwitch 9000-6 Slot

9C306 System Monitor

User’s Guide

Содержание 9C306

Страница 1: ...9031994 01 SmartSwitch 9000 6 Slot 9C306 System Monitor User s Guide...

Страница 2: ......

Страница 3: ...AL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED...

Страница 4: ...ich case the user will be required to correct the interference at his own expense WARNING Changes or modi cations made to this device which are not expressly approved by the party responsible for comp...

Страница 5: ...Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice co...

Страница 6: ...Notice iv...

Страница 7: ...f Band Management 3 3 COM1 and COM2 Ports 3 4 The Ethernet Port Interface Module EPIM 3 4 Chapter 4 Specifications Safety 4 1 EMC 4 1 Service 4 1 Physical 4 2 Environmental 4 2 Appendix A EPIM Specifi...

Страница 8: ...Contents vi...

Страница 9: ...hree out of band management interfaces are built into the 9C306 System Monitor Two interfaces are serial RS232 ports These ports support local management via a VT100 session Serial Line Internet Proto...

Страница 10: ...Introduction 1 2 Figure 1 1 The 9C306 System Monitor STATUS C O M 1 C O M 2 EPIM LNK EPIM T SM 9C306...

Страница 11: ...dicates the status of the System Monitor and the presence or absence of system alarms Related Manuals The manuals listed below should be used to supplement the procedures and technical data contained...

Страница 12: ...n the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is...

Страница 13: ...ector on the rear of the System Monitor Module 4 Examine it carefully checking for damage If any damage exists DO NOT install it Immediately contact Cabletron Systems for Technical Support 5 Install t...

Страница 14: ...h 9000 6 Slot 9C106 Chassis Setup and Installation Guide Figure 2 1 Installing the System Monitor STATUS C O M 1 C O M 2 EPIM LNK EPIM T SM 9C306 FAN 9C406 P O W E R R E D U N D A N C Y P O W E R R E...

Страница 15: ...s Fan status System voltages Fan Status The System Monitor Module monitors the operational status of the 9C406 Fan Module which maintains air ow through the chassis The System Monitor reports the fan...

Страница 16: ...ent Voltages above or below the acceptable voltage limits cause an alarm to be sent to the network manager Table 3 2 summarizes these acceptable voltage limits LANVIEW LED The LANVIEW LED on the front...

Страница 17: ...hassis as user data The 9C306 System Monitor provides three out of band management interfaces for managing the SmartSwitch 9000 system These interfaces are listed below Two serial communication ports...

Страница 18: ...Figure 3 2 RJ45 Communication Port Connector Table 3 4 details the pinout connections for an RJ45 communication port connector The Ethernet Port Interface Module EPIM The 9C306 System Monitor provides...

Страница 19: ...chassis complies with the following safety speci cations and standards UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 73 23 EEC EMC FCC Part 15 EN 55022 VCCI V 3 EN 50082 1 89 336 EEC Service The 9C306 Sys...

Страница 20: ...s 48 3 H x 30 5 W x 36 8 D centimeters 19 H x 1 2 W x 14 5 D inches Weight Unit 2 27 kilograms 5 pounds Shipping 2 27 kilograms 5 pounds Environmental Operating Temperature 5 to 40 C 40 to 104 F Opera...

Страница 21: ...ing It has an internal Cabletron Systems TPT T 10BASE T Twisted Pair Transceiver The slide switch on the EPIM T determines the crossover status of the cable pairs If the switch is on the X side the pa...

Страница 22: ...n Systems FOT F Fiber Optic Transceiver The EPIM F1 is equipped with SMA Connectors and the EPIM F2 is equipped with ST Connectors Figure A 2 shows both EPIMs Speci cations for the EPIMs are listed in...

Страница 23: ...Bm 13 0 dB 17 5 dB 62 5 125 m ber 10 0 dBm 12 0 dBm 16 0 dB 20 5 dB 100 140 m ber 7 0 dBm 9 0 dBm 19 0 db 23 5 dB Error Rate Better than 10 10 The transmitter power levels and receive sensitivity leve...

Страница 24: ...ivity Specifications LNK EPIM F3 RX TX Receive Sensitivity dBm Less Power More Power 40 35 30 25 20 15 10 5 0 Maximum Receive Input Power Transmitter Power At 25 C into 8 3 125 m fiber Minimum Sensiti...

Страница 25: ...operating environment For example the typical power output at 25 C is 16 4 dBm For a 4 C temperature increase multiply the typical coefficient 0 15 dBm by four and add the result to typical output po...

Страница 26: ...AUI cable Figure A 5 shows both modules Figure A 5 The EPIM A and EPIM X Table A 4 lists the DB15 pinouts Connector Shell Protective Ground Table A 4 EPIM A and EPIM x Pinouts Pin Number Represents Pi...

Страница 27: ...SM module Connecting a UPS to the System Monitor Module To connect a UPS to a System Monitor Module use the RJ45 DB9 adapter and the RJ45 cable included in the cable kit shipped with the System Monit...

Страница 28: ...RN until the Slot Selection Screen displays 2 At the Slot Selection Screen enter 0 zero to display the SM Con guration Screen 3 At the SM Con guration Screen cursor to the Application Field for the CO...

Страница 29: ...ng UPS Information about the operation of the UPS is obtained via Remote SNMP Management or locally by the LCD on the front of the UPS Refer to the UPS User s Guide provided by the vendor for detailed...

Страница 30: ...Uninterruptible Power Supply UPS B 4...

Отзывы: