Clearing System Storage or Password Using the Dip Switch Method
Enterasys 7100G-Series Hardware Installation Guide
B-3
Required Tools
Use the following tools to perform the procedure provided in this appendix:
•
ESD wrist strap
•
Phillips screwdriver capable of extending 6 or more inches into the unit
•
Flash light (recommended)
About the Mode Switches
on page B-4 shows the locations of the mode switches and the switch settings for
normal operation. These switches are set at the factory and rarely need to be changed. Switches
are numbered 1 through 8 from left to right.
Switch definitions and positions are as follows:
•
Switches 1– 6: For Enterasys Networks use only.
•
Switch 7: Clear Persistent Data. Changing the position of this switch from the up position to
the down position clears persistent data on the next power-up of the 7100G-Series switch. All
user-entered parameters, such as the IP address, system name, and so on, are reset to the
factory default settings. Once the system resets, you can either use the factory default settings
or reenter your own parameters.
•
Switch 8: Clear Admin Password. Changing the position of this switch from the up position to
the down position clears the admin password, and restores the factory default password on
the next power-up of the system. Once the 7100G-Series switch resets, you can either use the
factory default setting or reenter your own password.
Warning:
This unit may have more than one power supply cord. Disconnect two power supply
cords before servicing to avoid electric shock.
Advertencia:
Esta unida puede tener mas de un cable de fuente de poder. Desconectar dos cables
de fuentes de poder antes de dar servicio para prevenir riesgo eléctrico.
Warnhinweis:
Dieses Gerät hat mehrere Netzanschlüße, trennen Sie vor den Wartungsarbeiten
beide Netzanschlüsse vom Versorgungsnetz. zum Schutz vor elektrischen Schlägen.
Avertissement
: Cet élément pourrait avoir plus d'un câble d'alimentation. Déconnectez tous les
câbles d'alimentation avant d'effectuer les opérations de maintenance sur l'appareil afin de réduire
les risques d'électrocution.
Caution:
An antistatic wrist strap is required to perform the procedures in this appendix. Use the
antistatic wrist strap to minimize ESD damage to the devices involved.
Precaución:
Para llevar a cabo los procedimientos especificados en el apéndice deberá utilizar
una pulsera antiestática. Esta pulsera sirve para minimizar los efectos de las descargas de
electricidad estática.
Caution:
Read the appropriate sections to be fully aware of the consequences when changing
switch settings.
Only qualified personnel should change switch settings.
Precaución:
Si desea modificar la configuración del interruptor, lea las secciones correspondientes
para saber cuál será el resultado de hacerlo.
Estas modificaciones a la configuración sólo debe realizarlas personal calificado.
Note:
Do not change the position of Switch 8 unless it is necessary to reset the admin password to
its factory default setting.
Содержание 7100G Series
Страница 2: ......
Страница 12: ...x...
Страница 20: ...Getting Help xviii About This Guide...
Страница 46: ...Completing the Installation Pin Out Descriptions 2 22 Installation...
Страница 58: ...Using the OFFLINE RESET Button 3 12 Troubleshooting...
Страница 62: ...Regulatory Compliance A 4 Specifications...
Страница 84: ...Management of PoE Power to PDs D 4 About PoE Power over Ethernet...