NT PROPORTIONAL CONTROL VALVE, MODEL 6300
18
User Guide | Entegris, Inc.
Reference
PHYSICAL SPECIFICATIONS
—
Materials of
construction
Wetted parts
Body and diaphragms PTFE or PFA
Nonwetted parts
Polypropylene, Viton
®
, PVDF
Response time
C
V
1 – C
V
4
<2 seconds from 5 – 95% full scale
C
V
7 – C
V
8
<4 seconds from 5 – 95% full scale
Pressure range*
-14.5 to 60 psig
(C
V
1 – C
V
4)
-14.5 to 80 psig
(C
V
7 – C
V
8)
Over pressure limit
100 psig
Process temperature**
10° to 65°C (50° to 149°F)
Setpoint input signal
4–20 mA, 0–10 VDC, 0–5 VDC; separate homing line
also included
Enclosure
NEMA 5 / IP54
Connection type***
Flaretek tube fitting and Pillar Super 300 tube fitting
Approvals
Note: Preliminary specifications and features subject to change.
* Please consult the factory for pressure ranges from 60 to 80 psig.
** Please consult the factory for temperatures from 65° to 80°C (149° to 176°F).
*** For PrimeLock
®
connections and other options not listed, please contact Entegris.
ELECTRICAL SPECIFICATIONS
—
Input voltage
24 VDC ±10%, regulated
Input current
1.0 A nominal, 1.2 A peak
Impedance of setpoint input (voltage)
37 kOhm
Voltage drop, current setpoint input
<4.6 volts @ 20 mA @ 230 ohm
Electrical connection
FEP or PVC-jacketed cable