393930-2 Rev 0: 01.04.2020
60 |
P a g e
13.2.2 Alternative placement on wall
The unit can also be placed on a wall. You then need the use of a separate wall bracket. This does not
follow the unit and has to be ordered separate. (Ensy Art no: 01008045-2)
To avoid vibration from the unit towards building constructions it here is important that there are
placed 5 mm vibration damper on the back of the unit.
Two vibration gaskets screws for the
extra bracket follow the extra bracket.
One of the gaskets is placed in top of the
unit.
The other one you place approx. 60 mm
from the button of the unit so that id do
not will come in contact with the wall
bracket.
Then first put those two brackets in each end of the unit as
shown on page 16.
Then the wall bracket, with 10 mm gasket, is screwed to the
wall where it is wanted.
Use 8 pcs wood screws 5 x 40mm.
Then you can lift the unit and place it on the wall bracket. Then you use the brackets that follow the
unit, one in each end. Use 7 pcs wood screws 5 x 40mm, supplied with the unit, for each bracket
Wall bracket
Содержание AHU 200B
Страница 1: ...User manual and Installation Guide InoVent AHU 200 700 ...
Страница 2: ...393930 2 Rev 0 01 04 2020 2 P a g e ...
Страница 31: ...393930 2 Rev 0 01 04 2020 31 P a g e ...
Страница 41: ...393930 2 Rev 0 01 04 2020 41 P a g e ...
Страница 72: ...393930 2 Rev 0 01 04 2020 72 P a g e Ensy AS Mohagasvingen 1 N 2770 JAREN http www ensy no ...