order to work correctly. When the Auto Throttle Method is selected to Level Transducer and the
Level Type is set to
(Fill)
, the controller throttles the engine by increasing the RPM below the
deadband and decreasing the RPM above the deadband to maintain the desired level.
Empty:
when the Auto Start/Stop is selected as Level Transducer and the Level Type is set to
(Empty)
, it is necessary to set the level to start on a high value
(rising ↑) then stop on low value
(falling ↓) in order to work correctly. When the Auto Throttle Method is selected to Level Transducer
and the Level Type is set to
(Empty)
, the controller throttles the engine by decreasing the RPM
below the deadband and increasing the RPM above the deadband to maintain the desired level.
Factory set to Empty
Level P
–
(High Security): This selection is present when PID Auto Throttle Type selected and allows
adjustment of the Proportional setting of the PID loop when throttling.
Factory set to 0.020
Level I
–
(High Security): This selection is present when PID Auto Throttle Type selected and allows
adjustment of the Integral setting of the PID loop when throttling.
Factory set to 0.020
Level D
–
(High Security): This selection is present when PID Auto Throttle Type selected and allows
adjustment of the Derivative setting of the PID loop when throttling.
Factory set to 0.001
Temperature Transducer
–
(Medium Security): only present when selecting Temperature Transducer in the
Auto Start / Stop Function.
Start Temperature
–
(Medium Security): when the temperature drops to this set point, an auto start
will occur.
Factory set to 32 F
Stop Temperature
–
(Medium Security): when the temperature rises to this set point, an auto stop
will occur.
Factory set to 32 F
.
Start / Stop Timers
(Low Security)
There are eight timers to start and stop the engine, each with a Start Day and a Stop Day, a Start Time and a
Stop Time.
Countdown Timer
–
(Low Security): countdown timer will be active upon every
auto startup
until
the time is changed or disabled. It is used when it is desirable for a machine to run for a specific
amount of time unmonitored and then shut itself off when that time has expired or when an alternate
Stop condition has been met. Format of HH:MM:SS
Start / Stop Timer (1-3)
–
(Low Security):
each of the eight timers contains the ability to select from
the following parameters. Ensure the stop day and time are set as desired compared to the start day
and time.
Start / Stop Timer (4-8)
–
(Medium Security):
each of the eight timers contains the ability to select
from the following parameters. Ensure the stop day and time are set as desired compared to the start
day and time.
Days of the week are factory set to Off.
Start and Stop Times are factory set to 12.00.00 AM.
Start Day
Sunday
Monday