Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version:
2.9.23042; BTL: 02.09.10015.00]
Section 40
27
00-02-0996
2019-06-13
FPT (DEF Level
– Operator Warning) – Warning DEF Level below 10%
FPT (DEF Level
– Mid Level Inducement) – 65% of torque reduction; 40%
engine speed reduction ramped within 40 minutes
FPT (DEF Level
– Severe Inducement) – Engine commanded to low
idle within 30 minutes
JCB/Deutz - Emissions Malfunction Low
JCB/Deutz - Emissions Malfunction High
JCB - Catalyst Tank Level below 15%
JCB - Catalyst Tank Level below 5%
JCB
– DPF Emissions Filter Above 80%. Engine Refresh Required
JCB
– DPF Emissions Filter Above 90%. Engine Overloaded
JCB
– DPF Emissions Filter at 100%. Engine Plugged
JCB
– Inducement Level 2,3 or Final. Also used as Malfunction Indicator Lamp. This
icon also displays when the ECU sends a message to indicate to the operator a
malfunction has occurred with the engine. Contact your local engine manufacturer’s
service department for direction.