Section 40

 

00-02-1150

 

2018-10-08 

In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our 

specifications and designs at any time.  The latest version of this manual can be found at enovationcontrols.com. 

 

 

BEFORE BEGINNING INSTALLATION OF THIS MURPHY 

PRODUCT: 

 Read and follow all installation instructions. 

 Visually inspect this product before installation for 

any damage during shipping. 

 Disconnect all electrical power to the machine.  

Failure to do this before welding can result in 

damage to the panel and/or its components. 

 It is your responsibility to have a qualified technician 

install the unit and make sure the installation 

conforms to local codes including but not limited to 

double insulation and fire containment. 

 Observe all Warnings and Cautions in each section 

of these instructions. 

 The Murphy CONNECT product is a telemetry 

product designed for use in industrial environments 

for remote monitoring and control when used with 

Murphy’s PowerCore

®

 family of controllers. 

 

Contact Enovation Controls Technical Service if you have 

any questions or concerns at: +1 918-317-4100. 
IMPORTANT!  Improper use and operation of electronic 

products can be dangerous.  It is required that point-of-

operation guarding devices be installed and maintained.  

All such devices must meet OSHA and ANSI Machine 

safety standards.  The manufacturer shall not accept any 

responsibility for installation, application or safety of 

systems. 

 

 

 

 

 

 

Содержание Murphy CONNECT

Страница 1: ...00 02 1150 Section 40 2018 10 08 Murphy CONNECT Installation Manual Initial Release for U S Only ...

Страница 2: ...ian install the unit and make sure the installation conforms to local codes including but not limited to double insulation and fire containment Observe all Warnings and Cautions in each section of these instructions The Murphy CONNECT product is a telemetry product designed for use in industrial environments for remote monitoring and control when used with Murphy s PowerCore family of controllers ...

Страница 3: ...ware Installation 5 Inspecting Package Contents 5 Installation 5 Preparation 5 Installing the Module 5 Dimensions for Installation 6 Wiring Instructions 8 PIN Specifications for 8 Position Amphenol Connection 8 Accessories 10 Specifications 10 Electrical 10 Environmental 10 Mechanical 10 ...

Страница 4: ... remotely starting an engine when used in conjunction with Murphy s PowerCore controllers Please be cognizant at all times of hands and other objects that are in close proximity to the machine s being controlled as they may commence operation suddenly and without warning ...

Страница 5: ...spect each item for damage which sometimes occurs during shipping The items included in the box are Murphy CONNECT Telemetry Module P N 40 70 0525 includes CONNECT Module Dual Antenna with GPS and Cellular 3 meter 9 84ft length Quick Start Guide Installation Preparation Determine the location of where the CONNECT module will be installed Ensure there is proper room for the module to be mounted and...

Страница 6: ...Section 40 6 00 02 1150 2018 10 08 Dimensions for Installation Murphy CONNECT Module Inches mm ...

Страница 7: ...Section 40 7 00 02 1150 2018 10 08 Dimensions for Installation Antenna Inches mm ...

Страница 8: ...codes When the accessory harness is used the PowerCore controller in the panel will need the I O established prior to use TEC 10 and ML1000 Set the Digital Output 2 function to Ignition On On in Standby ML2000 Set the Digital Output 4 function to Ignition On On in Standby NOTE If the application is left in Auto mode a battery maintaining system should be installed for possible battery drain due to...

Страница 9: ...NECT front label The page should resemble the image below and allow one to see the items listed below for troubleshooting hardware and connectivity Application States whether the application is running or not running This should be running at this stage Version Version of the CONNECT device Connection States whether the device is connected to a cellular network Serial Number Provides Serial Number...

Страница 10: ...us RTU Wi Fi 2 4 GHz 802 11 b g n Troubleshooting Cellular LTE GPS Location Services Connection CONNECT Connector Amphenol AT06 08S Mating Connector Amphenol AT04 08PA Deutsch DT04 08PA Inputs 1 1 Digital Inputs Future Use Shared with Digital Output Outputs 1 1 Digital Output Future Use Shared with Digital Input Environmental Operating Temperature 30 C to 80 C 22 F to 176 F Storage Temperature 30 ...

Страница 11: ......

Отзывы: