background image

 

• 

Learning procedure for EnOcean transmitters, easy to operate 

 

 

 

Any further switching functions can be simply and flexibly implemented using the 
serial interface output of the RCM 120 that is connected to a low-priced 
microcontroller. The required output control logic can be easily programmed by the 

user. 

 

 

 
 

 

 

2.6 Learning of PTM 200 to RCM 110/120 Receivers 

The PTM 200 can be easily made known to the receiver RCM 110 or RCM 120 that has been 

set into learn mode through triggering a PTM 200 radio signal by operating the energy bow 

when pressing either the O-rod or the I-rod of the desired channel A or B. 

 

If the RCM 120 receiver is operated in mode 0 “Serial Interface”, telegrams from learned PTM 

transmitters are signed (see RCM 110/120 User Manual). 

 

 

 

 
©EnOcean GmbH, A. Anders 

 

Page 16 of 22 

 

 PTM 200 User Manual V1.1 

 

Содержание PTM200

Страница 1: ...Pushbutton Transmitter Device PTM 200 User Manual V1 1 March 2005...

Страница 2: ...or other rights of third parties are concerned liability is only assumed for devices not for the described applications processes and circuits EnOcean does not assume responsibility for use of device...

Страница 3: ...__________________________________________________ 13 2 4 PTM 200 Serial Data Communication via Receiver Device RCM 120_____________ 15 2 5 Basic Switching Features via Receiver Devices RCM 110 and RC...

Страница 4: ...sducer is actuated by a bow 1 which can be pushed from outside the device on the left or right by an appropriate pushbutton or switch rocker When the energy bow is pushed down electrical energy is cre...

Страница 5: ...STM solar powered wireless sensors CTM remote control and TCM bi directional IT interface and repeater 1 3 Features Overview Power supply power generation by rocker pressing Electro dynamic Power Gene...

Страница 6: ...ping rod travel operating force tbd at room temperature Number of operations 50 000 actuations tested according to VDE 0632 EN 60669 Cover material Hostaform POM Energy bow material tbd Color of devic...

Страница 7: ...1 Catwalks are not needed when using one rocker only Figure 3 PTM 200 top view note cut A B and C marking EnOcean GmbH A Anders Page 7 of 22 PTM 200 User Manual V1 1...

Страница 8: ...Figure 4 PTM 200 cut A Figure 5 PTM 100 cut B and C Labeling area EnOcean GmbH A Anders Page 8 of 22 PTM 200 User Manual V1 1...

Страница 9: ...ees corresponds to 1 5 mm energy bow travel Figure 7 and 8 PTM 200 side view 1 5 Environmental Conditions Operating temperature 25 up to 65 C Storage temperature 40 up to 85 C 85 up to 100 C for 1h ma...

Страница 10: ...01 A200 PTM 200 Rocker Model Development Tool Please send an Email to info enocean com IGS Data of PTM 200 Rocker Model see Chapter 3 1 Free Download from www enocean com IGS Data of PTM 200 device ca...

Страница 11: ...Energy Bow Power Generator Converts pressure on the energy bow into electrical energy Power Converter Electronic converter unit for generating the device DC power supply Processor Converts the contac...

Страница 12: ...ch device of Type 2 unlike PTM 100 N message One or two contact nipples have been pressed when activating the energy generator Message with nipple code and pressed released event status of the energy...

Страница 13: ...pter 3 6 of this paper 2 3 2 Modulation process As modulation process EnOcean uses incoherent amplitude modulation ASK Digital amplitude modulation enables the implementation of very efficient energy...

Страница 14: ...sions remains extremely low Statistically viewed the transmission reliability is still greater than 99 99 in the case of 100 radio sensors that transmit once every minute This means that even large of...

Страница 15: ...nd RCM 120 Radio Receiver Devices are used to receive and process PTM telegrams generated and transmitted by EnOcean radio transmitters Via functional control outputs open collector these devices can...

Страница 16: ...2 6 Learning of PTM 200 to RCM 110 120 Receivers The PTM 200 can be easily made known to the receiver RCM 110 or RCM 120 that has been set into learn mode through triggering a PTM 200 radio signal by...

Страница 17: ...able from EnOcean that can be easily snapped onto the PTM 200 device case Figure 14 Rocker Model for PTM 200 Figure 15 Rocker model snapped onto the device Please note that pressing the rocker sends a...

Страница 18: ...type and location of the antennas of the receiver and the transmitter type of terrain and degree of obstruction of the link path sources of interference affecting the receiver and dead spots caused by...

Страница 19: ...ter must not be exceeded Permanent transmitters such as radio earphones are not allowed For conventional applications it must be ensured that the PTM 200 radio device is not operated more than 6000 ti...

Страница 20: ...l interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following me...

Страница 21: ...supply for EVA PCB Convenient equipment case 4 2 Field Intensity Meter EPM 100 The EPM100 is a mobile field intensity meter that helps the engineer to find the best installation positions for sensor...

Страница 22: ...5 DECLARATION OF CONFORMITY Will be available with PTM 200 series release EnOcean GmbH A Anders Page 22 of 22 PTM 200 User Manual V1 1...

Отзывы: