Learning procedure for EnOcean transmitters, easy to operate
Any further switching functions can be simply and flexibly implemented using the
serial interface output of the RCM 120 that is connected to a low-priced
microcontroller. The required output control logic can be easily programmed by the
user.
2.6 Learning of PTM 200 to RCM 110/120 Receivers
The PTM 200 can be easily made known to the receiver RCM 110 or RCM 120 that has been
set into learn mode through triggering a PTM 200 radio signal by operating the energy bow
when pressing either the O-rod or the I-rod of the desired channel A or B.
If the RCM 120 receiver is operated in mode 0 “Serial Interface”, telegrams from learned PTM
transmitters are signed (see RCM 110/120 User Manual).
©EnOcean GmbH, A. Anders
Page 16 of 22
PTM 200 User Manual V1.1