USER MANUAL
PTM 535 / PTM 535U / PTM 535J
–
ENOCEAN TRANSMITTER MODULE
© 2019 EnOcean | www.enocean.com
F-710-017, V1.0
PTM 535 / 535J User Manual | v1.5 | September 2020 | Page 22/36
4.8
Execution sequence
The following steps have to be executed exactly in the below given order:
1.
“Get
the device info
”
(show device info)
2.
“
Read
PTM 535”
the current configuration (show config and do a backup)
3.
Modify the configuration fields (security key, telegram data, etc.)
4.
“
Write
to PTM 535”
the modified configuration
Quit Segger info window with no (details see PTM Config help)!
5.
Save configuration to file (if you want to configure additional PTM 535)
6.
Load configuration from file
7.
“Write to PTM 535” the modified configuration
to additional module
Quit Segger info window with no (details see PTM Config help)!
PTM 535 Configurator uses Segger tools to communicate with the radio chip. If a
window pops up
“
to unlock
”
the device,
you must select NO
(for details, see
PTM 535 Config help). Due to radio approval requirements, trying to unlock the
device will cause the module to stop radio transmission.
Radio module configuration is only possible with the EnOcean PTM 535 Configu-
rator tool. Follow exactly the above written sequence to chance PTM 535 config-
uration. Due to radio approval requirements, trying to use an incorrect configu-
ration will lead the module to stop radio transmission.
Additional care has to be taken to configure correct values for DATA and STATUS
fields. Otherwise PTM 535 might not work properly together with repeaters or
receivers.