2.0 Instrument Features

2.1 Exterior Features

The exterior of the instrument is shown in 

Figure 1

. The exterior features are as follows:

 

Feature

 

Description

 

Enclosure

 

A NEMA-12 plastic box, approximately 10x8x6, with a clear hinged front cover.

 

Sample Air Hose

 

A five foot long hose to conduct a sample of the air from the source to the instrument.
See 

Figure 1A

.

 

Sample Port

 

The fitting for the sample air hose.

 

Sample/Calibration

 

Valve

 

A red handled ball valve which directs the air from either the sample or the calibrate port.
The handle points at the port, sample or calibrate, which is providing the air to the
instrument

 

Calibration Port

 

The entrance for the calibration gas.  The quick release fitting mates with one on the
calibration adapter.

 

Front Cover Latch

 

A quick-release latch that holds the clear front cover in place, and is capable of being
padlocked if desired.

 

Humidifier Tube

 

Located under a black sheet metal cover.  Is a tube that extracts moisture from the
atmosphere and adds it to dry sample air, before it is presented to the carbon monoxide and
oxygen sensors.

 

Line Cord

 

A cord to supply 110 

V

AC

 to the equipment.  Not illustrated.

 

Audio Alarm

 

A loud horn activated by certain alarm conditions.

 

Mounting Flanges

 

Flanges with holes for mounting the enclosure to a vertical surface.

Regulator

(Not supplied)

 

To connect to the compressed air line.  Line pressure to the 

M

ED 

A

IR 

2000 

should be set to

55 

PSI

.  See note 

Figure 1A

2.2 Display Panel Features

The display panel, shown in 

Figure 1

, is viewed through the clear front cover of the enclosure, and is accessed by

opening the cover. Features are as follows:

 

Feature

 

Description

 

Display

 

A 2 line, 16 character per line, LCD with backlight.  The numerical values of gas
concentrations, and other information are displayed.

 

Flowmeter

 

A flow indicator located at the output of the sample flow stream, which indicates
quantitatively the flow of sample air or calibration gas through the instrument.

 

Visual Alarms

 

On both sides of the display, a red LED for each sensor on the instrument.

 

Near the center of the panel,. a green power LED and a red fault LED,

 

Pushbutton Switches

 

There are three of these, located near the center of the panel; they are yellow
rectangular membrane switches.  They are:

 

Option Switch

 

The top left switch.

 

 

Select Switch

 

Directly to the right of the option switch.

 

 

Alarm Acknowledge/

Audio Defeat Switch

 

Directly under the option switch.

 
 

Содержание MED AIR 2000

Страница 1: ...MCN 167 09 20 00 MCN 176 03 06 98 MCN 200 09 04 98 MCN 204 01 29 99 MCN 237 09 21 00 MCN 274 05 01 02 MCN 327 02 03 05 MCN 332 04 15 05 MED AIR 2000 Operation and Maintenance Manual Andersen Medical...

Страница 2: ......

Страница 3: ...peration Condition 8 4 2 Alarm Set Points 8 4 3 Alarm Latching 8 4 4 Audio Defeat 9 4 5 Display 9 4 6 Operational Menu 9 4 7 Fault Indications 10 4 7 1 Low Flow Indication 10 4 7 2 Other Fault Indicat...

Страница 4: ...SPLAY 8 TABLE 4 FACTORY ALARM SET POINTS 8 FIGURE 5 MED AIR 2000 OPERATION MENU FLOW CHART 9 FIGURE 6 MED AIR 2000 MAINTENANCE MENU FLOW CHART 11 FIGURE 7 CONNECTION OF CALIBRATION GAS CYLINDER 13 TAB...

Страница 5: ...ected verified and properly packaged at our company and delivered to the carrier in good condition When it was picked up by the carrier at ENMET it legally became your company s property If your shipm...

Страница 6: ...ord A cord to supply 110 VAC to the equipment Not illustrated Audio Alarm A loud horn activated by certain alarm conditions Mounting Flanges Flanges with holes for mounting the enclosure to a vertical...

Страница 7: ...put See note below Audio Alarm Flow Meter Strain Relief for Line Cord Fault LED SELECT Switch Power LED OPTION Switch ALARM ACKNOWLEDGE ALARM DEFEAT Switch Visual Alarm O2 If Oxygen option is installe...

Страница 8: ...ld Housing The sample manifold the carbon monoxide and oxygen sensors are located under this small aluminum housing Not illustrated in figure 2 see Figure 8 2 4 Power Supply The power supply circuit i...

Страница 9: ...rs Upright plumb and level vertical orientation of the instrument is necessary for proper operation Mount the instrument on an appropriate vertical surface using the mounting flanges provided Avoid ar...

Страница 10: ...play The instrument may go into alarm briefly but the sensors stabilize quickly If the instrument persists in alarm acknowledge the alarm by pressing the ALARM ACKN AUDIO DEFEAT switch If alarm persis...

Страница 11: ...trip in the positions given in Table 3 Table 3 Outputs for 4 20mA for S N 599 and below Position Channel Function Range 16 CO Ground 4 mA 0 ppm 17 CO 4 to 20 mA 20 mA 100 ppm 18 DP Ground 4 mA 100 F 1...

Страница 12: ...is activated If the oxygen content of the sample air decreases below the deficiency alarm set point the associated red LED is lit the associated relay chances state and the audio alarm is activated If...

Страница 13: ...concentration is given in per cent by volume When sample flow is reduced below a limit the display switches from Flow yes to Flow no or from Flow y to Flow n 4 6 Operational Menu The operational menu...

Страница 14: ...nt 4 7 2 Other Fault Indications Other fault indications are associated with sensor zero and calibration activities and are described in the maintenance section 5 0 of this manual 4 8 Dew Point Sensor...

Страница 15: ...u is accessed with the OPTION and SELECT switches The maintenance menu diagram is shown in Figure 6 Maintenance Menu Flow Chart From the operational display press the OPTION switch twice run MAINTENAN...

Страница 16: ...which locks the correct digit in place and moves the cursor one digit to the right Continue this process until the four digit key is complete When a valid key is inserted in this manner the display is...

Страница 17: ...tandard and is best avoided The best zero gas is a cylinder of 20 9 oxygen in nitrogen with no CO present This is available in the calibration kit listed in section 6 0 Pressing the OPTION switch at t...

Страница 18: ...ph 5 1 2 above When this procedure is complete ATTACH SPAN GAS SPAN 20 is displayed to indicate that the correct span gas for this procedure is 20 ppm CO in a mixture of 20 9 oxygen in nitrogen Do Not...

Страница 19: ...rated with calibrating the CO sensor and the span voltage is close to but not greater then 0 38V an adjustment may be capable of being made to extend the life of the sensor Follow the procedure foe ca...

Страница 20: ...T switch to lock the digit in place and move the cursor one digit to the right When all four digits of the new key have been selected NEW XXXX is displayed Record the new key without it the maintenanc...

Страница 21: ...ur hours before recalibrating When recalibrating it is not necessary to make a voltage adjustment 5 3 Humidifier Tube The humidifier tube is used to assure that the CO and oxygen sensors are not subje...

Страница 22: ...ove Shorting Clip Figure 9 Manifold Figure 10 Location of Parts for Replacement Manifold Cover Humidifier Tube Humidifier Tube Flow Control Orifice Oxygen Sensor CO Voltage adjustment Potentiometer CO...

Страница 23: ...1000 Fuse 1 0 Amp 5x20mm 67016 1106 Sensor Oxygen 67020 1200 Sensor CO for units S N 299 and below 67016 1204 Sensor CO for units S N 300 and above 73070 009 Orifice 73108 002 Humidifier Tube 03401 00...

Страница 24: ...ET shall not be liable for any loss or damage caused by the improper use of the product The purchaser indemnifies and saves harmless the company with respect to any loss or damages that may arise thro...

Страница 25: ...te the assessment of the degree of danger that he or she is exposed to Based upon knowledge of the effects of CO the Occupational Safety and Health Authority OSHA has set limits on exposure to CO in t...

Страница 26: ...ENMET Corporation MED AIR 2000 22 Notes...

Страница 27: ...processing delays ENMET charges a one hour minimum billing for all approved repairs with additional time billed to the closest tenth of an hour All instruments sent to ENMET are subject to a minimum 3...

Страница 28: ......

Страница 29: ...___________ Your Phone _______________________ Your PO Reference Number _______________ Your FAX _______________________ Payment Terms T COD Check one T VISA MasterCard______________________ ________...

Страница 30: ......

Отзывы: