1.0 Introduction

The 

M

ED 

A

IR 

2000

is a gas and dew point detection instrument that monitors compressed air from medical air supply

systems for certain hazards to the user.  The instrument is available with sensors that monitor air for carbon monoxide
(CO), for variations in the oxygen (O

2

) content and for dew point.  The sensors can be used alone or up to three sensors

can be used together.  In the instrument, a sample of the compressed air is passed over electrochemical CO and O

2

sensors, a solid state dew point sensor and the resultant electrical outputs are used to evaluate the air for the target
gases.  Some features of the instruments are as follows:

ƒ

 

continuous monitoring of the sample air

ƒ

 

continuous 

LCD

 display of gas and vapor concentrations

ƒ

 

menu driven operational and maintenance controls

ƒ

 

menu driven calibration procedure

ƒ

 

audio and visual alarms indicate unsafe conditions

ƒ

 

alarm relay contacts available on terminals

ƒ

 

a fault relay and visual fault alarm

ƒ

 

flowmeter plus low flow fault indication and display

ƒ

 

alarm acknowledgement capability including audio defeat

ƒ

 

mA outputs for each target gas

ƒ

 

NEMA-12 packaging

N

OTE

:

All specifications stated in this manual may change without notice.

1.1 Unpack

Unpack the 

M

ED 

A

IR 

2000

and examine it for shipping damage.  If such damage is observed, notify both 

ENMET

 customer

service personnel and the commercial carrier involved immediately.

Regarding Damaged Shipments

N

OTE

:

 It is your responsibility to follow these instructions.  If they are not followed, the carrier will

not honor any claims for damage.

‰

 

This shipment was carefully inspected, verified and properly packaged at our company and delivered to the carrier in good
condition.

‰

 

When it was picked up by the carrier at 

ENMET

, it legally became your company’s property.

‰

 

If your shipment arrives damaged:

 

Keep the items, packing material, and carton “As Is.”  Within 5 days of receipt, notify the carrier’s local office and request
immediate inspection of the carton and the contents.

 

After the inspection and after you have received written acknowledgment of the damage from the carrier, contact 

ENMET

Customer Service for return authorization and further instructions.  Have your Purchase Order and Sales Order numbers
available.

‰

 

ENMET

 either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage, usually

$100.00.  Repair or replacement charges above that value are your company’s responsibility.

‰

 

The shipping company may offer optional insurance coverage. 

ENMET

 only insures shipments with the shipping company

when asked to do so in writing by our customer.  If you need your shipments insured, please

 forward a written request to

ENMET

 Customer Service.

Regarding Shortages

If there are any shortages or questions regarding this shipment, please notify 

ENMET

 Customer Service within 5 days of receipt at

the following address:

ENMET

 Corporation

680 Fairfield Court

Ann Arbor, MI 48108

734-761-1270 734-761-3220 Fax

1.2 Check Order

Check, the contents of the shipment against the purchase order.  Verify that the 

M

ED 

A

IR 

2000

 is received as ordered.  If there are

accessories on the order, ascertain that they are present.  Check the contents of calibration kits.  Notify 

ENMET

 customer service

personnel of any discrepancy immediately.

1.3 Serial Numbers

Each 

M

ED 

A

IR 

2000 

is serialized.  These numbers are on tags on the equipment and are on record in an 

ENMET

 database.

Содержание MED AIR 2000

Страница 1: ...MCN 167 09 20 00 MCN 176 03 06 98 MCN 200 09 04 98 MCN 204 01 29 99 MCN 237 09 21 00 MCN 274 05 01 02 MCN 327 02 03 05 MCN 332 04 15 05 MED AIR 2000 Operation and Maintenance Manual Andersen Medical...

Страница 2: ......

Страница 3: ...peration Condition 8 4 2 Alarm Set Points 8 4 3 Alarm Latching 8 4 4 Audio Defeat 9 4 5 Display 9 4 6 Operational Menu 9 4 7 Fault Indications 10 4 7 1 Low Flow Indication 10 4 7 2 Other Fault Indicat...

Страница 4: ...SPLAY 8 TABLE 4 FACTORY ALARM SET POINTS 8 FIGURE 5 MED AIR 2000 OPERATION MENU FLOW CHART 9 FIGURE 6 MED AIR 2000 MAINTENANCE MENU FLOW CHART 11 FIGURE 7 CONNECTION OF CALIBRATION GAS CYLINDER 13 TAB...

Страница 5: ...ected verified and properly packaged at our company and delivered to the carrier in good condition When it was picked up by the carrier at ENMET it legally became your company s property If your shipm...

Страница 6: ...ord A cord to supply 110 VAC to the equipment Not illustrated Audio Alarm A loud horn activated by certain alarm conditions Mounting Flanges Flanges with holes for mounting the enclosure to a vertical...

Страница 7: ...put See note below Audio Alarm Flow Meter Strain Relief for Line Cord Fault LED SELECT Switch Power LED OPTION Switch ALARM ACKNOWLEDGE ALARM DEFEAT Switch Visual Alarm O2 If Oxygen option is installe...

Страница 8: ...ld Housing The sample manifold the carbon monoxide and oxygen sensors are located under this small aluminum housing Not illustrated in figure 2 see Figure 8 2 4 Power Supply The power supply circuit i...

Страница 9: ...rs Upright plumb and level vertical orientation of the instrument is necessary for proper operation Mount the instrument on an appropriate vertical surface using the mounting flanges provided Avoid ar...

Страница 10: ...play The instrument may go into alarm briefly but the sensors stabilize quickly If the instrument persists in alarm acknowledge the alarm by pressing the ALARM ACKN AUDIO DEFEAT switch If alarm persis...

Страница 11: ...trip in the positions given in Table 3 Table 3 Outputs for 4 20mA for S N 599 and below Position Channel Function Range 16 CO Ground 4 mA 0 ppm 17 CO 4 to 20 mA 20 mA 100 ppm 18 DP Ground 4 mA 100 F 1...

Страница 12: ...is activated If the oxygen content of the sample air decreases below the deficiency alarm set point the associated red LED is lit the associated relay chances state and the audio alarm is activated If...

Страница 13: ...concentration is given in per cent by volume When sample flow is reduced below a limit the display switches from Flow yes to Flow no or from Flow y to Flow n 4 6 Operational Menu The operational menu...

Страница 14: ...nt 4 7 2 Other Fault Indications Other fault indications are associated with sensor zero and calibration activities and are described in the maintenance section 5 0 of this manual 4 8 Dew Point Sensor...

Страница 15: ...u is accessed with the OPTION and SELECT switches The maintenance menu diagram is shown in Figure 6 Maintenance Menu Flow Chart From the operational display press the OPTION switch twice run MAINTENAN...

Страница 16: ...which locks the correct digit in place and moves the cursor one digit to the right Continue this process until the four digit key is complete When a valid key is inserted in this manner the display is...

Страница 17: ...tandard and is best avoided The best zero gas is a cylinder of 20 9 oxygen in nitrogen with no CO present This is available in the calibration kit listed in section 6 0 Pressing the OPTION switch at t...

Страница 18: ...ph 5 1 2 above When this procedure is complete ATTACH SPAN GAS SPAN 20 is displayed to indicate that the correct span gas for this procedure is 20 ppm CO in a mixture of 20 9 oxygen in nitrogen Do Not...

Страница 19: ...rated with calibrating the CO sensor and the span voltage is close to but not greater then 0 38V an adjustment may be capable of being made to extend the life of the sensor Follow the procedure foe ca...

Страница 20: ...T switch to lock the digit in place and move the cursor one digit to the right When all four digits of the new key have been selected NEW XXXX is displayed Record the new key without it the maintenanc...

Страница 21: ...ur hours before recalibrating When recalibrating it is not necessary to make a voltage adjustment 5 3 Humidifier Tube The humidifier tube is used to assure that the CO and oxygen sensors are not subje...

Страница 22: ...ove Shorting Clip Figure 9 Manifold Figure 10 Location of Parts for Replacement Manifold Cover Humidifier Tube Humidifier Tube Flow Control Orifice Oxygen Sensor CO Voltage adjustment Potentiometer CO...

Страница 23: ...1000 Fuse 1 0 Amp 5x20mm 67016 1106 Sensor Oxygen 67020 1200 Sensor CO for units S N 299 and below 67016 1204 Sensor CO for units S N 300 and above 73070 009 Orifice 73108 002 Humidifier Tube 03401 00...

Страница 24: ...ET shall not be liable for any loss or damage caused by the improper use of the product The purchaser indemnifies and saves harmless the company with respect to any loss or damages that may arise thro...

Страница 25: ...te the assessment of the degree of danger that he or she is exposed to Based upon knowledge of the effects of CO the Occupational Safety and Health Authority OSHA has set limits on exposure to CO in t...

Страница 26: ...ENMET Corporation MED AIR 2000 22 Notes...

Страница 27: ...processing delays ENMET charges a one hour minimum billing for all approved repairs with additional time billed to the closest tenth of an hour All instruments sent to ENMET are subject to a minimum 3...

Страница 28: ......

Страница 29: ...___________ Your Phone _______________________ Your PO Reference Number _______________ Your FAX _______________________ Payment Terms T COD Check one T VISA MasterCard______________________ ________...

Страница 30: ......

Отзывы: