Introduction
This owner’s guide shows you how to install, maintain and generally get the most from your l-shaped
thermostatic shower valve. Please retain this document for future reference.
We recommend
installation by a qualified plumber only.
Operating Specification
Pressure
§
Minimum working pressure – 0.5 bar
§
Recommended working pressure 1 – 3 bar
§
Maximum working pressure – 5 bar
Pressure above 5 bar must be reduced via a pressure reducer. To maximize efficiency of the valve, the
operating pressures should be balanced.
Water Temperature
§
Hot water supply maximum temperature - 85°C
§
Hot water supply recommended temperature - 65°C
§
Cold water supply - 10°C - 25°C
IMPORTANT. A minimum 10°C difference between outlet temperature and hot supply temperature
must be maintained at all times.
Pre-installation notes
Before proceeding, please note:
§
The valve must be installed in compliance with local water authority byelaws and water supply
byelaws.
§
Read all the instruction manual before proceeding.
§
Only begin the installation when you have all the necessary tools ready.
§
Please check that all the components are in the shower valve box.
Aftercare
When installing or using tools, extra care must be taken to avoid damaging the finish or the fitting. To
maintain the appearance of this fitting, please ensure it is cleaned regularly using a clean soft damp
cloth only. Abrasive cleaners or detergents must not be used as they may cause surface deterioration.