SPL-G LED street luminaire
Mounting instruction
MPL
, MPL-T
parameter table:
Electrical scheme:
IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. The luminaire is not allowed to be placed in the water or close to fire resource and high temperature place.
2. Before installing this fixture or doing any maintenance, make sure to turn off the power
supply at the circuit breaker or fuse box.
3.
Make sure that the
l
uminaire is not damaged before install and use. If the glass is broken or damaged it must be
replaced.
4. Only the authorized electrician can
i
nstall the l
uminaire
, and the wire should
comply with the
national standards.
5.
Input cable can be 2
, 3, 4 or 5
cores and the min cross-sectional area of the conductor should be
1.5 mm2.
The input cable should meet
requirements of IEC 60227 or IEC 60245.
6.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced
by the manufacturer or his service agent in order to avoid a hazard
.
LED quantity
8 - 16
Power
1
0-50W
Weight max
3.2 kg
Product dimensions:
2
Projected area -
0,02 m
max. The max mounting height -
10
m
220-240V AC
50-60Hz
LED
Driver
module
1 /
3
IK
09
Ta
-40°C
+50°C
Maintenance of luminaire must be done accorrding the standard CIE 154-2003.
Recommended period of maintenance - every 3-4 years.
Cleaning must be done with soft material and soapy water.
Do not use agressive chemicals or solvents!
The information in this document is subject to change without notice.
http://www.enimlighting.com
0.5m
7
. Check to make sure that all the fixture connections have been properly made and the fixture is grounded to avoid
potential electrical shocks.
8
.
The light source of luminaire is non-user replaceable. It can only be replaced by the manufacturer or his service agent.
MAINTENANCE OF LUMINAIRE
Caution, Risk of Electric Shock.
Disconect all power sources before servicing.