background image

MPL and MPL-T LED street luminaire

Mounting instruction  

MPL

, MPL-T

 parameter table:

Electrical scheme:

IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS

 

1. The luminaire is not allowed to be placed in the water or close to fire resource and high temperature place.

2. Before installing this fixture or doing any maintenance, make sure to turn off the power

supply at the circuit breaker or fuse box.

    

3. 

l

Make sure that the uminaire is not damaged before install and use. If the glass is broken or damaged it must be 

    replaced.
4. Only the authorized electrician can nstall the l

, and the wire should 

 with

 national standards.

i

uminaire

comply

 the

5. 

,  , 4 or 5

Input cable can be 2 3

 cores and the min cross-sectional area of the conductor should be 1.5 mm2.

    The input cable should meet 

 of 

requirements

IEC 60227 or IEC 60245.

6. Check to make sure that all the fixture connections have been properly made and the fixture is grounded to avoid
    potential electrical shocks.

LED quantity

8 - 32

Power

1

0-1

2

0W

Weight max

5 kg

Product dimensions:

Projected area - 

0,001

 m max. The max mounting height - 

16

 m

490

90.

Ø 61

25

260

35

102.8

422

220-240V AC

50-60Hz

LED 

Driver

module

Controller

optional

MPL

MPL-T

106.8

1

13.5

MPL

MPL-T

100

106.5

MPL

MPL-T

172.5

1 / 5

MPL

MPL-T

1

10

IK 09

Ta

-40°C 

+50°C

Pending

Pending

MAINTENANCE OF LUMINAIRE

Maintenance of luminaire must be done accorrding the standard CIE 154-2003.
Recommended period of maintenance - every 3-4 years.
Cleaning must be done with soft material and soapy water.
Do not use agressive chemicals or solvents! 

 

The information in this document is subject to change without notice.

http://www.enimlighting.com

Updated 2021.06.01

Содержание MPL

Страница 1: ...nductor should be 1 5 mm2 The input cable should meet of requirements IEC 60227 or IEC 60245 6 Check to make sure that all the fixture connections have been properly made and the fixture is grounded to avoid potential electrical shocks LED quantity 8 32 Power 10 120W Weight max 5 kg Product dimensions 2 Projected area 0 001 m max The max mounting height 16 m 490 90 Ø 61 25 260 35 102 8 422 220 240V ...

Страница 2: ...deg 5 deg 10 deg 15 deg 20 deg 5 deg 10 deg 20 deg 15 deg 25 deg 0 deg 5 deg 10 deg 15 deg 20 deg 5 deg 10 deg 20 deg 15 deg Setting the angle Adapting to pole position 2 5 1 2 3 The information in this document is subject to change without notice http www enimlighting com Updated 2021 06 01 ...

Страница 3: ...2 3 2 Power cable size 3x1 5 mm 2 2x1 5 mm 2 5x1 5 mm 2 4x1 5 mm Ø 5 14 The input cable should meet the requirement of IEC 60227 or IEC 60245 L xxcm MPL L N D D N L OPTIONAL N L D D N L OPTIONAL CLASS II CLASS I MPL T Cable connection 4 3 1 2 5 6 2 Power cable size 3x1 5 mm 2 2x1 5 mm 2 5x1 5 mm 2 4x1 5 mm Ø 5 14 The input cable should meet the requirement of IEC 60227 or IEC 60245 The information...

Страница 4: ...ting instructions MPL AND MPL T 4mm 10 Nm Mounting on a pole 4 5 8 7 9 10 1 2 4mm Or 0 8 Nm The information in this document is subject to change without notice http www enimlighting com Updated 2021 06 01 ...

Страница 5: ...n in this document is subject to change without notice 5 5 http www enimlighting com 1 2 2 1 1 Remove protection cap 2 Mount and fix node Mounting of ZHAGA node 1 2 2 1 1 Remove shorting cap 2 Mount and fix node Mounting of NEMA node Updated 2021 06 01 ...

Отзывы: