![Enginko mcf88 MCF-LW12TERWP Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/enginko/mcf88-mcf-lw12terwp/mcf88-mcf-lw12terwp_operating-manual_2412934011.webp)
2022/08/30 08:47
9/18
manual_mcf-lw12terwp
e n g i n k o . s u p p o r t . c e n t e r - https://www.enginko.com/support/
At the end of the procedure the battery level displays 100%.
2.6 Firmware update
Save the firmware file (.FW) on the smartphone, and upload it with LoraTool App:
During the update, do not move the smartphone untill the end message.
3. Measures
3.1 Period
Period is the interval (in minutes) between one measure and the next one. The sensor sends one
measures for every transmission. Value can be between 15 and 65535 minutes (default: 30 minutes).
Period interval can be set with App or with downlink command.
3.2 Temperature
3.3 Pressure
3.3.1 Altitude compensation
When the sensor is not installed at the sea level, the reading of barometric pressures at other
elevations must be compensated. Set the right altitude value with LoRa Tool app: