DOOR SENS
(+) (-)
12~24 VAC/VDC
EG IN
OUTPUT 1
N.C. COM N.O.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FULL AUTO
BACKLIT
KEY ALARM
K or A
Backlit
jumper
K or A
jumper
Connection terminals
Connection wires
8
ENFORCER Access Control Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc.
Connection Wires
Wire Color
Function
Description
1
Red
Tamper
Tamper switch output, N.C. contact, max. 50mA@24VDC. Connect to the
N.C. 24-hour protection zone of an alarm if needed.
2
Black
Tamper
3
Grey
Green LED (-)
Connect to a device to trigger the green LED.
4
Green
Green LED (+)
5
Light Blue
Red LED (-)
Connect to a device to trigger the red LED.
6
Yellow
Red LED (+)
7
White
Ground (-)
Common ground output. Common with wire 15.
8
Pink
K or A Output
Transistor ground output, max. 100mA@24VDC. See “K or A” jumper
information below for programming details.
9
White/Brown
Output #2 COM
Output #2. NO/NC/COM, relay output, max. 1A@30VDC
10
Blue
Output #2 N.O.
11
Purple
Output #2 N.C.
12
White/Red
Output #3
Transistor ground output, max. 100mA@24VDC
13
Orange
Output #1 Inhibit
Output #1 inhibitor. N.O. input, connect to Interlock control of second
keypad if needed so that if one keypad is used to open a door, the other is
temporarily disabled.
14
Brown
Interlock control
Interlock control. N.O. input, connect to Output #1 inhibit of second
keypad if needed so that if one keypad is used to open a door, the other is
temporarily disabled.
15
Light Green
Ground (-)
Common ground output. Common with wire 7.
16
White/Orange Duress Output
Transistor ground output, max. 100mA@24VDC. Triggers a silent alarm or
other device when the user enters a duress code.
Connection Terminals
Terminal
Description
Output #1 N.C.
Output #1. NO/NC/COM, relay output,
max. 1A@30VDC
Output #1 COM
Output #1 N.O.
Egress In
N.O. Pushbutton contact to ground. Press
button to initiate door unlock output
12/24 VAC/VDC Connect to a 12/24 VAC/VDC power supply.
Observe polarity.
Door Sensor
Connect to an optional N.C. sensor such as a
magnetic contact to monitor if a door is open
or closed. Connect to ground if not used.
Wiring Diagram:
Jumpers
Backlit
Full
Dim backlit during standby. Full backlit for 10 seconds after any button press.
Auto
No backlit during standby. Full backlit for 10 seconds after any button press.
K or A
K
Switch to ground (-) for 10 seconds after any button pressed.
A
Switch to ground (-) when alarm occurs.