background image

2

7⁄8

” (73mm)

1

½

” 

(38mm)

4

5⁄8

” 

(117mm)

6

ENFORCER Access Control Keypad with Proximity Card Reader

SECO-LARM U.S.A., Inc.

Overview:

LED Indicators and Keypad Sounds:

Parts List:

1x Keypad 

1x Back box 

2x Installation screws 

2x Mounting screws 

1x Diode

 

1x Manual

Keypad Sounds and LEDs

Status

Sounds

(1)

Green/Red/Amber LED (Center)

In programming mode

Steady ON

Successful key entry

1 Beep

1 Flash

Successful code/card entry

2 Beeps

2 Flashes

Unsuccessful code/card entry

5 Beeps

Power up delay

Continuous beeping

Continuous flashing

Output relay activation

(2)

1-Sec long beep

In standby mode

(3)

1 Flash/sec

System refresh mode

2 Beeps

Fast flashing for 2.5 min

Card/code already stored

1 Long beep

Real time clock stopped after 

power loss

Continuous 3 fast beeps 

every 5 seconds

NOTE

:

1.  Keypad sounds can be programmed ON or OFF (see page 25).

2.  Output relay activation sounds can be programmed ON or OFF (see page 25).

3. 

Green center LED flashing during standby mode can be programmed ON or OFF 

 

(see page 26).

LED Indicators

Red LED (Left)

Green/Red/Amber LED (Center)

Green LED (Right)

Steady

Available for free connection

Programming mode (green)

Output #1 disabled (red)

Available for free connection

Flashing

Standby mode (green)

Inhibit mode paused (red/amber)

Keypad Locked (red/amber)

Содержание SK-1131-SPQ

Страница 1: ...SK 1131 SPQ Access Control Keypad with Proximity Card Reader Manual ...

Страница 2: ...athode for DC use only Mounting screws Installation screws 2 ENFORCER Access Control Keypad with Proximity Card Reader SECO LARM U S A Inc Quick Installation Guide Mounting Diagram Quick Wiring Diagram This page is for installers looking to do a basic installation and programming of the keypad For more in depth installation and programming instructions see the Table of Contents on page 4 SK 1131 S...

Страница 3: ...r of digits as the master code see page 24 Programming Instructions Follow the instructions below if the following covers your needs A new master code A single 4 digit user code for all users and no proximity cards One output to unlock a door A 3 second delay time in opening the door after the output is activated 1 Turn off the beeping before the 1 minute power up period ends 12 2 Change the maste...

Страница 4: ...User Codes and Proximity Cards 16 17 Programming Visitor Codes for Output 1 17 18 Programming Duress Codes 19 20 Programming the Output Mode and Output Timing 21 Programming the Real Time Clock 22 Programming the Output 1 Auto Disable Time 22 23 Programming the Wrong Code System Lock Up 24 Programming the User Code Entry Mode 24 25 Programming the Keypad Sounds 25 Programming the Output Relay Acti...

Страница 5: ...le for output 1 100 001 100 for output 2 100 001 100 for output 3 Up to 50 01 50 possible temporary visitor codes which can be programmed for one time or limited time use 1 99 hours Output 1 Form C relay 1A 30VDC max Output 2 Form C relay 1A 30VDC max Output 3 Transistor ground 100mA 24VDC Outputs 1 2 and 3 can be programmed to activate for up to 99 999 seconds nearly 28 hours Tamper output N C Dr...

Страница 6: ...elay activation 2 1 Sec long beep In standby mode 3 1 Flash sec System refresh mode 2 Beeps Fast flashing for 2 5 min Card code already stored 1 Long beep Real time clock stopped after power loss Continuous 3 fast beeps every 5 seconds NOTE 1 Keypad sounds can be programmed ON or OFF see page 25 2 Output relay activation sounds can be programmed ON or OFF see page 25 3 Green center LED flashing du...

Страница 7: ...o the keypad according to the wiring diagram on page 8 7 Finish assembly by attaching the keypad to the back box with the included installation screws 1 Always disconnect power before servicing the keypad Do not apply power until all connection wiring is completed 2 The keypad must be properly grounded Use a minimum 22AWG wire connected to the common ground output wire 7 white or wire 15 light gre...

Страница 8: ...o Interlock control of second keypad if needed so that if one keypad is used to open a door the other is temporarily disabled 14 Brown Interlock control Interlock control N O input connect to Output 1 inhibit of second keypad if needed so that if one keypad is used to open a door the other is temporarily disabled 15 Light Green Ground Common ground output Common with wire 7 16 White Orange Duress ...

Страница 9: ...etic Door Contact 12VDC Power Supply SK 1131 SPQ SK 1131 SPQ Keypad 1 SK 1131 SPQ Keypad 2 9 ENFORCER Access Control Keypad with Proximity Card Reader SECO LARM U S A Inc Sample Applications Stand Alone Door Lock In this application the keypad is connected to a single door lock and an egress pushbutton Inter Lock System Using Two Keypads In this application two keypads are each connected to separa...

Страница 10: ...ard fob code For enhanced security the user can be required to also enter a code after tapping a proximity card fob The code may be unique to each card or to a group of users or a common code can be used with all cards Security Levels There are four possible security levels for the SK 1131 SPQ 1 Card only The most basic convenient level of security Hold a previously programmed proximity card over ...

Страница 11: ...tion or for programming Enter and Exit Programming Mode All programming of the keypad is done in programming mode 1 Enter programming mode xxxx NOTE XXXX is the master code 0000 is the default master code see Programming the Master Code on page 13 to program a new master code The center green LED will turn to a steady ON to indicate that the keypad is in programming mode 2 Exit programming mode Th...

Страница 12: ...des for output 1 No default must be programmed 17 18 41 Duress codes for output 1 No default must be programmed 19 20 42 Duress codes for output 2 No default must be programmed 19 20 43 Duress codes for output 3 No default must be programmed 19 20 51 Output mode for output 1 5 Second output momentary 21 52 Output mode for output 2 5 Second output momentary 21 53 Output mode for output 3 5 Second o...

Страница 13: ...en reset to their default values and are ready to be re programmed At this point the keypad is still in programming mode The master code is used to enter programming mode The master code does not serve as a user code for activating outputs 1 2 or 3 1 Make sure the keypad is in programming mode see Enter and Exit Programming Mode on page 11 2 Enter new master code 01 xxxx NOTE XXXX represents the n...

Страница 14: ... new super user code 02 xxxx NOTE XXXX represents the new super user code which can be 4 to 8 digits long There can be only one super user code for the keypad Programming a new super user code will overwrite the previous super user code The master code super user code common user codes and user codes cannot be the same Deleting the Super User Code This function is useful for protecting the premise...

Страница 15: ...less of programming 2580 9 NOTE For more information on programming timed or toggle mode see Programming the Output Mode and Output Timing on page 21 The center LED will flash red and amber while output 1 is disabled For safety reasons the egress button works regardless of whether output 1 is enabled or disabled via the super user code The super user code continues to operate output 1 even while t...

Страница 16: ...ead of a card 2 User code only Type in a 4 to 8 digit user code to activate outputs 1 2 or 3 3 Card Unique user code The most secure level This code is programmed separately for each card and can be unique to the card or the same code can be used for a group or department The card and code must be used together to operate the output 4 Card Common user code All valid proximity cards can be programm...

Страница 17: ...rogram a user code for user ID 010 for output 1 10 2 010 2275 3 Delete a proximity card for output 1 10 5 READ CARD 4 Delete code or proximity card stored in position 002 for output 1 10 5 002 5 Delete all users for output 1 10 0999 6 Program a proximity card for user ID 001 for output 1 for use with a common user code 10 4 001 READ CARD 7 Program a proximity card for user ID 023 for output 2 for ...

Страница 18: ... time code This code can only be used once by a visitor after which it is automatically deleted 01 to 99 Set the duration the visitor code will be valid from 1 to 99 hours Visitor Codes A visitor code can be 4 to 8 digits long and must have the same length as the master code if the keypad is used in auto code entry mode see Programming the User Code Entry Mode on pages 24 25 All visitor codes are ...

Страница 19: ...User Codes and Proximity Cards on page 16 The duress code should be easy to remember For instance it can be the same as a user s normal user code but with a single digit changed as by subtracting or adding 1 to the first or last digit of the code For example if the user code is 1369 a good duress code might be 2369 When programming duress codes use this general formula AA BB CCCC a Output b Duress...

Страница 20: ...code cannot deactivate the duress output Only a normal user code card super user code or a master code can deactivate the duress output NOTE A duress code can also be used in conjunction with a user card to activate the duress output However a user card alone cannot activate the duress output Examples In these examples assume that 1360 is an output 1 duress code and that 1369 is a user code 1 Acti...

Страница 21: ... A Output B Output Mode and Time Outputs 51 Output 1 52 Output 2 53 Output 3 Output Mode and Time 0 Start stop toggle mode In this case the output starts when a user code and or user card is entered and stops when a user code and or card is entered 1 to 99999 The output triggered by a user code and or user card lasts 1 to 99 999 seconds nearly 28 hours before automatically turning off default 5 se...

Страница 22: ... auto disable time is programmed losing power will cause the keypad to beep in groups of 3 every 5 seconds To deactivate this alert either reset the real time clock or clear the output 1 auto disable time If the output 1 auto disable time is not programmed losing power will not cause the keypad to beep The keypad can be programmed so that output 1 is disabled for a certain period of time every day...

Страница 23: ...isable time use this general formula 56 HHMM HHMM 56 Program Output 1 Auto Disable Time HHMM Start Time HHMM End Time Start Time Start time for output 1 auto disable time HH represents hours and MM represents minutes in the military 24 hour time format from 00 00 to 23 59 End Time End time for output 1 auto disable time HH represents hours and MM represents minutes in the military 24 hour time for...

Страница 24: ... can be deactivated using any user code or user card or via the super user code 5 to 10 After 5 to 10 successive false attempts using incorrect user codes or user cards the keypad will lock for 15 minutes or until the super user code is used as follows SUPER USER CODE 9 00 No system lock up will happen NOTE The keypad s center LED will flash red and amber to show that the keypad is locked The dure...

Страница 25: ...eeps 5 beeps are disabled However the warning and power up delay beeps remain active This provides for a quieter work environment To Program To enable keypad audible mode default 71 1 To enable keypad silent mode 71 0 NOTE This programming function only impacts the keypad sounds It does not impact the output relay activation sounds see Programming the Output Relay Activation Sounds below Programmi...

Страница 26: ...ad can be programmed to beep when a door has been forced open The keypad beep can be set to activate for 1 to 999 seconds 1 Door forced open warning OFF default 80 0 2 Door forced open warning ON 80 ttt NOTE TTT represents the beep and alarm output active time which can be set from 1 to 999 seconds If programmed for door forced open warning the keypad will beep if the door is forced open without u...

Страница 27: ...en door is closed Programming the Door Open Alarm and Timing When the keypad is connected to a magnetic contact or other door monitoring device it can be programmed to trigger the alarm output for 1 to 999 seconds if the door is opened In this case if the alarm output is triggered the output either automatically ends at the end of the programmed time or when a user code or super user code is input...

Страница 28: ...ton momentarily for silent egress operation 2 Momentary contact with warning beep Press the egress button momentarily The keypad will beep for the programmed delay time before letting the door open to warn that someone is preparing to exit the protected area 3 Momentary contact with warning beep and alarm Press the egress button momentarily The keypad will beep for the programmed delay time and ac...

Страница 29: ...is tells the keypad how long to wait after the egress button is pressed before activating output 1 Examples 1 Momentary mode Press the egress button and the keypad will beep for 5 seconds before output 1 activates 90 2 5 2 Hold button to activate Press and hold the egress button for 10 seconds and the keypad will beep for those 10 seconds before output 1 activates 90 5 10 3 Return to default setti...

Страница 30: ...eypad s power is fully discharged 3 Reconnect the power The keypad will beep repeatedly for one minute 4 While the keypad is beeping press the egress button once to stop the beeping 5 Enter the DAP code 2828 6 The center green LED will now turn ON indicating that the keypad is ready for a new master code to be programmed NOTE See Programming the Master Code on page 13 for how to program a new mast...

Страница 31: ...ashing center green LED indicates the card is accepted and the keypad is waiting for the Common user code 3526 1 Long beep indicates that the door can be opened Security Level 4 Card Unique user code READ CARD 2 Short beeps and a rapidly flashing center green LED indicates the card is accepted and the keypad is waiting for the Unique user code 2468 1 Long beep indicates that the door can be opened...

Страница 32: ...ating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to the replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damage of any kind to the purchaser or anyone else This lim...

Отзывы: