The ENFORCER Room Monitor can be used to monitor the occupancy status of rooms in high traffic areas: restrooms, 
fitting rooms, etc. The Room Monitor uses PIR and phototransistor sensors to monitor the occupancy of a room. The 
single-room receiver includes additional features, such as a built-in buzzer and service button input, for applications where 
occupants may need assistance. Two-room receivers are ideal for monitoring multiple rooms at once. 

1x  RM-R100-TLQ 

1x  RM-R100-RB1Q 

2x  USB Power cords* 

1x  Receiver decal 

1x  Manual 

 

 

*The RM-R100-RB1Q, RM-R100-R2Q, and RM-R100-RLQ come with 1x USB power cord. 

Model 

RM-R100-TLQ 

RM-R100-RB1Q 

RM-R100-R2Q 

Description 

Transmitter 

Single-room, 1-ch receiver 

Two-room, 2-ch receiver 

Indicators 

LED 

Buzzer and LED 

LED 

Memory capacity 

N/A 

15 Transmitter codes, per channel 

Current 
draw 

Standby 

2mA@12VDC 

6mA@12VDC 

Active 

15mA@12VDC max. 

35mA@12VDC max 

Transistor ground rating 

100mA max. 

N/A 

PIR Sensor range 

~16' (5m) 

N/A 

Phototransistor sensitivity 

≥320Lux 

N/A 

Door input 

NO or NC 

N/A 

RF Range* 

100' (30m) 

Operating frequency 

 433.92MHz 

Operating voltage 

5VDC via micro USB or 5~12 VDC via terminals 

Connections 

Screw terminals 

Operating temperature 

-4°~167° F (-20°~75° C) 

Dimensions 

2

1

/

2

"x

15

/

16

"x1

7

/

8

" (64x24x48 mm)  

Weight 

1.8-oz (50g) 

 

Specifications:  

Introduction:  

Parts List for Room Monitor Kit (RM-R100-KB1Q):  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overview:  

Pairing button 

Micro USB Power 
input 

PIR Sensor

Phototransistor

LED Indicator 

Phototransistor ON/OFF jumper 

Door sensor input (DNO+)

GND 

Service output (SOP-) 
 

V+ 

Service input, N.O. (SIP-) 

LED ON/OFF jumper 
 

PIR ON/OFF jumper

Transmitter  

Wire pass-through

Service/Ch2 pairing button 
Ch1 Pairing button 

Micro USB power 
input 
 

LED Indicators* 

Antenna 

Buzzer 

(1-Ch receiver only) 

GND 
Service input, N.O. (SIP)  
(1-Ch receiver only) 

V+ 

Buzzer ON/OFF jumper (1-Ch receiver only) 

Receiver 

*2-Ch receiver has 4 LED indicators (2 for each channel). 

Wire pass-through 
 

*Actual operating range will vary greatly depending on the installation and operating environment. 

ENFORCER Room Monitor 

SECO-LARM U.S.A., Inc. 

3

 

Setting Reminder Time:  

Clear Channel Memory:  

Display Channel Memory:  

Installation Notes:  

Installation:  

 

 

 

 

 

 

 

 

 

 

 

NOTE: 

Pairing button must be pressed within 5 seconds of powering on the transmitter/receiver. 

1.

 

Power on receiver/transmitter unit. 

2.

 

Press pairing button and count number of times LED flashes 

3.

 

Repeat step 2 until desired reminder time is set. See table below for reminder time settings. 

To clear all codes from a channel’s memory, press the channel pairing button for 3 seconds or more until the channel 
indicator LED begins flashing. Release, and then press the button again for 3 seconds or more until the LED stops flashing. 
The LED will then flash twice to indicate that all codes associated with that channel have been deleted. 

To see how many codes have been learned by a channel, press that channel’s pairing button once. The number of codes 
stored in the channel’s memory corresponds with the number of times the channel's LED indicators flash. 

# of Flashes 

Reminder time 

Disabled 

3min 

5min 

10min 

15min 

20min 

30min 

 

1.

 

Mount the transmitter and receiver units in locations where they are not exposed to weather or moisture, and where 
they are not surrounded by metal. Metal will block the RF signal, resulting in reduced range. 

2.

 

For best results, mount the transmitter and receiver units with no more than one wall in between the two. 

3.

 

If using USB power, make sure to replace the cover before connecting to the mini USB port. 

4.

 

The door contact input should only be used for applications where the door being monitored is usually kept open. 

5.

 

If an N.C. magnetic contact is being used to monitor the door then a 100kΩ resistor (not included) should be installed 
between the voltage and door contact inputs. See pg. 4, 

Using a Magnetic Contact for Door Monitoring,

 for more details.

Each receiver channel can learn the codes of up to 15 different transmitters on a first-in, first-out basis. The procedure for 
code learning a new transmitter is as follows: 
1.

 

Once the receiver has been powered on for over 5 seconds, press the pairing button of the desired channel for 
3 seconds or more. The channel's LED will start to flash quickly to indicate that it is in learning mode. 

2.

 

While the LED is flashing, press the button of the transmitter to be learned one time. The receiver's channel indicator 
LED will flash once to indicate the transmitter has been successfully learned. After the transmitter has been learned, 
the receiver will automatically exit learning mode. To learn further codes, repeat step 1 to re-enter learning mode. 

NOTES: 

 

The channel's indicator LED will flash a maximum of 30 seconds. If no transmitter button is pressed during this time, 
the receiver will automatically exit learning mode, and the LED will turn off.

 

 

If the code being learned has already been learned, the channel indicator LED will turn steady ON and then start 
flashing again. The code will not be learned a second time.

 

 

One channel can learn the codes of a maximum of 15 transmitter buttons. If you attempt to learn a sixteenth 
transmitter code, the earliest code learned will be deleted and the new code will be learned. 

Code Learning a New Transmitter: 

Mounting holes 

Wire 

pass-through 

Fig. 1

 

1.

 

Find a suitable location to mount the transmitter/receiver. 

2.

 

Remove the top cover and PCB. Place the bottom case on the wall where 
it is to be mounted, and mark the wall through the two mounting holes. 

3.

 

Screw two mounting screw (not included) into the marked locations, and 
slide the bottom case down onto the screws (see Fig. 2). 

4.

 

Tighten the screws as needed, but take care not to overtighten and ensure 
the case can still be removed by sliding. 

NOTE:

 Mark the location of the wire pass-through hole now, if needed. 

5.

 

Remove the bottom case from the wall and feed wires through the wire 
pass-through holes (PCB and case) and wire as necessary. 

6.

 

Replace the top cover and slide back onto mounting screws. 