ENFORCER Plug-and-Play Backup Power
4
SECO-LARM U.S.A., Inc.
Backup time is shorter than
claimed
•
On initial installation, be sure that batteries have been charged for
24 hours before testing backup time
The power plug does not fit my
unit
•
You may need to provide a power tip adapter to connect to your
device (two adapters, both male and female for the SB-L10V1-20Q)
Device does not turn on when
installed
•
Check to see that all plugs are firmly connected at the device, the
Backup Power unit, power adapter, and the AC wall outlet
•
Check to see that the AC outlet is live
•
Ensure that the Backup Power unit's power LED is lit
•
Check for a short or overload. The Backup Power unit is designed
to cut power when a short-circuit or overload is detected
•
Ensure that the battery’s polarity is correct and reverse if needed
(SB-P1012-26Q)
•
Check that the device’s voltage is compatible (12VDC for the
SB-P1012-26Q, and either 5, 7.5, 9, or 12VDC for the
SB-L10V1-20Q)
•
If using the SB
-
L10V1-20Q, press the “Off/Reset” button to reset
voltage output
During a power outage, power is
not provided to device
•
Check for a short or overload. The Backup Power unit is designed
to cut power when a short-circuit or overload is detected
•
Ensure that the Backup Power unit battery’s polarity is correct and
reverse if needed (SB-P1012-26Q only)
The alarm sounds (long beep) and
the red alarm LED
(SB-L10V1-20Q) is lit
•
Ensure that the input voltage is either 5, 7.5, 9, or 12VDC
•
Ensure that the original power adapter is working and providing
power to the Backup Power unit
•
Ensure that the device current draw is no more than 10W
•
Check for a short-circuit at the device
Note:
Your Enforcer Backup Power unit was originally supplied with a high-quality battery by GE
™
. When
replacing a battery, for continued dependability and safety, be sure to use the same GE
™
18650 Li-Ion battery
(for SB-P1012-26Q). Using an inferior battery could result in a fire or explosion.
Troubleshooting:
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for 1 (one) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Phone: (949) 261-2999 | (800) 662-0800 Email: [email protected]
®
PITPW3
MiSB-x10xx-2xQ_150609.docx
SB-P1012-26Q / SB-L10V1-20Q
Plug-and-Play Backup Power
Manual
ENFORCER Plug-and-Play Backup Power units provide automatic continual power to CCTV
cameras, routers, modems, VOIP phone systems, alarm systems, or other small electronic devices
during power outages. In addition, they include protection against short-circuits and power surges.
The high quality GE
™
batteries are protected from short-circuit, overcharge, over-discharge, and
overload.
Note: All trademarks named herein are the property of their respective owners.
SB-L10V1-20Q In-line Backup Power
SB-P1012-26Q Plug-in Backup Power