background image

ENFORCER Rack-Mount DC CCTV Power Supply 

4

 

SECO-LARM U.S.A., Inc. 

Power does not turn on 

 

Check front panel LEDs and rear main fuse. 

 

Ensure the power cord is firmly in its socket. 

Power cycles on and off 

 

The unit may be overheating

Check for heat sources nearby and ensure 

ventilation holes are free from obstruction. 

Voltage drop is large 

 

Use 18 gauge or thicker wire. 

The camera case is hot 

 

Check that the correct power is being supplied. 

 

Replacing the Main Fuse:  

 
 
 

12VDC Switching CCTV 

Power Supplies 

Power Adapters 

4-Channel "Brick"  

Power Supply 

 

 

 

PC-U1820-PULQ shown 

ST-UV12-S2.0Q shown 

PA-U0405-NULQ 

 

Also Available from 

SECO-LARM

®

:  

Troubleshooting:  

SECO-LARM

 

®  

U.S.A., Inc.

 

16842 Millikan Avenue, Irvine, CA 92606  Website: www.seco-larm.com 

Phone: (949) 261-2999  |  (800) 662-0800  Email: [email protected] 

 

 

PICSN7 

 

MI_PH-U1820-PULQ_190521.docx 

 

NOTICE: 

The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves 

the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the 

property  of  SECO-LARM U.S.A., Inc.  or  their  respective  owners.  Copyright © 2019  SECO-LARM U.S.A., Inc.  All  rights 

reserved.  

WARRANTY:

 

This SECO-LARM product is warranted against defects in material and workmanship while used in normal 

service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or 

replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if 

damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper 

or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not 

operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM 

and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event 

shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind 

to the purchaser or anyone else. 

CAUTION: 

To reduce the risk of electric shock, do not open the product case. There are no user serviceable parts inside. 

Refer servicing to qualified service personnel. 

 

CAUTION

 

 

RISK OF SHOCK 

DO NOT OPEN

 

 

1.

 

The main fuse is at the back of the unit, between the AC cord socket and the ON/OFF switch. 

2.

 

To check or replace the fuse, first power down the unit and disconnect the power cord. 

3.

 

Use a flat-head screwdriver to gently lever the fuse holder out at the place indicated in the 

diagram below.  Be careful not to damage the soft plastic fuse holder with the screwdriver. 

 

 

  

® 

 
 
 

 

 

 
 

PH-U1820-PULQ 

Rack-Mount DC CCTV Power Supply 

Manual 

Features: 

 

18 Outputs, 20A total 

PTC fuse protected outputs, 16 outputs at 

1.6A and 2 outputs at 5A  

11.7~13.6 VDC field-adjustable output 

110/220 VAC Input with selection switch 

LCD Display of output voltage and total 

output current 

LED Status indicators for each output 

Removable screw terminal blocks for 

convenient installation and reliable 

connections  

For rack mounting or stacking on a shelf 

Compact 1U size fits standard racks 

Attractive, high-tech industrial design 

 

AUDIO/VIDEO APPARATUS 

26BZ 

Содержание PH-U1820-PULQ

Страница 1: ...ustable output 110 220 VAC Input with selection switch LCD Display of output voltage and total output current LED Status indicators for each output Removable screw terminal blocks for convenient installation and reliable connections For rack mounting or stacking on a shelf Compact 1U size fits standard racks Attractive high tech industrial design AUDIO VIDEO APPARATUS 26BZ ...

Страница 2: ... terminal block 1x Manual Input voltage 110 220 VAC with selection switch Input fuse Glass 10A Number of outputs 18 Maximum current per output Ch 1 2 5A Ch 3 18 1 6A Output fuse type PTC Output voltage Adjustable 11 7 13 6 VDC Rack mount height 1U Operating humidity Up to 90 non condensing Operating temperature 14 86 F 26 30 C Dimensions 13 4 x171 2 x77 8 45x445x200 mm Weight 5 lb 7 oz 2 47kg Spec...

Страница 3: ...rating or heat sensitive equipment 5 To prevent shock do not open the housing There are no user serviceable parts inside 1 Decide on a location to install the unit away from moisture high humidity heat sources etc 2 Make sure there is enough space around the unit so air can flow in and out for cooling 3 Be sure ventilation holes are not blocked by other equipment rack housing walls etc 4 To avoid ...

Страница 4: ... used in normal service for one 1 year from the date of sale to the original customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage ...

Отзывы: