ENFORCER E-920B Скачать руководство пользователя страница 1

Page 1

HOW IT WORKS

When triggered by an alarm system, the

E-920B

 Voice Dialer can dial up to four

telephone numbers and/or pager numbers.
Each number can contain up to 32 digits
(including  pound  (#)  tones  and  pauses
used  in  pager  numbers).

When the dialer is activated, the LCD will
show the numbers dialed at each step of
the  dialing  process.  When  the  dialer
makes a connection, one of two possible
16-sec. voice messages will be delivered.
The user can record each message to
respond to one or two inputs. Each
message is then delivered repeatedly for
one minute to ensure the full message is
received. This process will repeat for each
number  stored.

If within 8 to 10 rings there is no
connection, the E-920B will automatically
dial the next programmed number.

If the dialer has attempted to dial each
number one time and the unit is still in the
alarm state, the dialer will attempt to call
all numbers a second time. All busy
numbers will be dialed a third time.

Note: If the dialer is programmed to call
a voice pager service which requires
operator assistance, the service should
be notified in advance regarding the
meaning of the message.

Summary

:  The E-920B Voice Dialer

will automatically dial up to four
telephone numbers and deliver one
of two different messages when
triggered by an alarm system.

SECO-LARM

®

 U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA  92606

Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326

Website: www.seco-larm.com

E-mail: [email protected]

MiE920B_0910.pmd

WARRANTY:

 

 

This SECO-LARM product is warranted against defects in material and workmanship

while used in normal service for a period of one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse,
neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason
SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects
in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or
repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral,
incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

PIKVR1

Installation Manual

ENFORCER

®

E-920B

Voice Dialer

VOICE DIALER Installation Manual

SECO-LARM U.S.A., Inc.

Page 8

1. Contact the company or person who

will be called by each of the recorded
telephone numbers prior to performing
an actual test in the "OPERATE" mode.
Advise the people at the numbers
dialed that you are conducting a test,
and ask them to confirm with you that
the message was received and
understood.

2. Turn the power "OFF".

3. Connect the dialer to the phone line

(see page 3).

4. The sensor should not be in the alarm

mode.  If it is, the unit will start dialing
immediately.

5. Turn the power "ON".

6. Use the "MODE" button to place the

unit in the "OPERATE" mode.

TESTING THE UNIT — DIALING OUT TO THE PROGRAMMED
NUMBERS

Note: To ensure proper operation, the E-920B must be tested at least once in the
OPERATE mode, and the dialer must be connected to the phone line.

Note: Prior to operation of the E-920B, be sure the power source is correct and the
wiring is connected properly.  It is recommended that the E-920B be tested under
simulated alarm conditions and that the user receive confirmation of transmission
from the numbers dialed.

CHECKING THE STATUS OF SENSORS

7. Trigger input #1 or #2 to simulate an

alarm condition.

8. At this point the dialer should begin

to dial the telephone numbers #1 to
#4.  The outgoing message (1 or 2,
depending on which trigger is
tripped) will be delivered for one
minute  once  the  dialer  makes  a
connection.

Note:

 The message will not be heard

because  the  test  is  just  a  controlled
alarm event.

9. The message will  repeat  for #2, #3

and #4 telephone numbers.  If a
number is busy or unanswered after
8 to 10 rings, that number will be
skipped, and dialed again once the
other numbers have finished dialing.
Numbers that are still busy will be
dialed a third and final time.

The "TEST" mode can be used to check the current status of both sensors during
installation. Press the "MODE" button and select the "TEST" mode. The status of both
sensors  will  be  simultaneously  shown  on  the  LCD.

a. S1-O: Indicates the relay contact of sensor #1 is "OPEN".

b. S1-C: Indicates the relay contact of sensor #1 is "CLOSED".

c. S2-O: Indicates the relay contact of sensor #2 is "OPEN".

d. S2-C: Indicates the relay contact of sensor #2 is "CLOSED".