HOW IT WORKS
When triggered by an alarm system, the
E-920B
Voice Dialer can dial up to four
telephone numbers and/or pager numbers.
Each number can contain up to 32 digits
(including pound (#) tones and pauses
used in pager numbers).
When the dialer is activated, the LCD will
show the numbers dialed at each step of
the dialing process. When the dialer
makes a connection, one of two possible
16-sec. voice messages will be delivered.
The user can record each message to
respond to one or two inputs. Each
message is then delivered repeatedly for
one minute to ensure the full message is
received. This process will repeat for each
number stored.
If within 8 to 10 rings there is no
connection, the E-920B will automatically
dial the next programmed number.
If the dialer has attempted to dial each
number one time and the unit is still in the
alarm state, the dialer will attempt to call
all numbers a second time. All busy
numbers will be dialed a third time.
Note: If the dialer is programmed to call
a voice pager service which requires
operator assistance, the service should
be notified in advance regarding the
meaning of the message.
Summary
: The E-920B Voice Dialer
will automatically dial up to four
telephone numbers and deliver one
of two different messages when
triggered by an alarm system.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: [email protected]
MiE920B_0910.pmd
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship
while used in normal service for a period of one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse,
neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason
SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects
in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or
repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral,
incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
PIKVR1
Installation Manual
ENFORCER
®
E-920B
Voice Dialer
VOICE DIALER Installation Manual
SECO-LARM U.S.A., Inc.
Page 8
1. Contact the company or person who
will be called by each of the recorded
telephone numbers prior to performing
an actual test in the "OPERATE" mode.
Advise the people at the numbers
dialed that you are conducting a test,
and ask them to confirm with you that
the message was received and
understood.
2. Turn the power "OFF".
3. Connect the dialer to the phone line
(see page 3).
4. The sensor should not be in the alarm
mode. If it is, the unit will start dialing
immediately.
5. Turn the power "ON".
6. Use the "MODE" button to place the
unit in the "OPERATE" mode.
TESTING THE UNIT — DIALING OUT TO THE PROGRAMMED
NUMBERS
Note: To ensure proper operation, the E-920B must be tested at least once in the
OPERATE mode, and the dialer must be connected to the phone line.
Note: Prior to operation of the E-920B, be sure the power source is correct and the
wiring is connected properly. It is recommended that the E-920B be tested under
simulated alarm conditions and that the user receive confirmation of transmission
from the numbers dialed.
CHECKING THE STATUS OF SENSORS
7. Trigger input #1 or #2 to simulate an
alarm condition.
8. At this point the dialer should begin
to dial the telephone numbers #1 to
#4. The outgoing message (1 or 2,
depending on which trigger is
tripped) will be delivered for one
minute once the dialer makes a
connection.
Note:
The message will not be heard
because the test is just a controlled
alarm event.
9. The message will repeat for #2, #3
and #4 telephone numbers. If a
number is busy or unanswered after
8 to 10 rings, that number will be
skipped, and dialed again once the
other numbers have finished dialing.
Numbers that are still busy will be
dialed a third and final time.
The "TEST" mode can be used to check the current status of both sensors during
installation. Press the "MODE" button and select the "TEST" mode. The status of both
sensors will be simultaneously shown on the LCD.
a. S1-O: Indicates the relay contact of sensor #1 is "OPEN".
b. S1-C: Indicates the relay contact of sensor #1 is "CLOSED".
c. S2-O: Indicates the relay contact of sensor #2 is "OPEN".
d. S2-C: Indicates the relay contact of sensor #2 is "CLOSED".