Destination 2.3 Insert Installation and Operation Manual
33
9.4.2 Installation Raised of More than 5"
If the extension of the masonry hearth is raised at least 5" (127 mm) from the floor protection, a non-
combustible material, without an R-value, must extend at least 16" (406 mm in USA) or 18" (457 mm in
Canada) in front of the unit.
9.4.3 R Value
There are two ways to calculate the R-value of the floor protection. First, by adding the R-values of materials
used, or by the conversion if the K factor and thickness of the floor protection are given.