background image

 

45595A 

Printed in Canada 

29-04-2016 

 

INSTALLATION 

AND OPERATION 

MANUAL

 

Destination 2.3 

Insert 

(EB00021 model)

 

US ENVIRONMENTAL PROTECTION 

AGENCY PHASE II CERTIFIED 

WOOD INSERT 

 

 

Safety tested according to ULC S628, 

UL 737 and UL 1482 Standards  

by an accredited laboratory 

 

 

 

 

www.enerzone-intl.com 

Stove Builder International Inc. 

250, rue de Copenhague, St-Augustin-de-Desmaures 

(Quebec) Canada  G3A 2H3 

After-sale service: 418-908-8002      E-mail: [email protected]    

READ AND KEEP THIS MANUAL FOR REFERENCE 

This  manual  is  available  for  free  download  on  the  manufacturer’s  web  site.  It  is  a 
copyrighted  document.  Re-sale  is  strictly  prohibited.  The  manufacturer  may  update  this 
manual  from  time  to  time  and  cannot  be  responsible  for  problems,  injuries,  or  damages 
arising out of the use of information contained in any manual obtained from unauthorized 
sources. 

Содержание Destination 2.3 Insert

Страница 1: ...250 rue de Copenhague St Augustin de Desmaures Quebec Canada G3A 2H3 After sale service 418 908 8002 E mail tech sbi international com READ AND KEEP THIS MANUAL FOR REFERENCE This manual is available for free download on the manufacturer s web site It is a copyrighted document Re sale is strictly prohibited The manufacturer may update this manual from time to time and cannot be responsible for pro...

Страница 2: ...may overheat To reduce the risk of fire follow the installation instructions in this manual exactly Contact local building or fire officials about restrictions and installation inspection requirements in your area Please read this entire manual before you install and use your new insert You may need to get a building permit for the installation of this insert and the chimney that it is connected t...

Страница 3: ...s That Should Not be Burned 12 3 2 How to Prepare or Buy Good Firewood 12 3 2 1 What is Good Firewood 12 3 2 2 Tree Species 12 3 2 3 Log Length 13 3 2 4 Piece Size 13 3 2 5 How to Dry Firewood 14 3 2 6 Judging Firewood Moisture Content 15 3 3 Manufactured Logs 15 4 Operating Your Insert 16 4 1 The use of a fire screen 16 4 2 Your First Fires 16 4 3 Lighting Fires 16 4 3 1 Conventional Fire Startin...

Страница 4: ... Installation 29 8 Clearances to Combustible Material 30 8 1 Location of the Certification Label 30 8 2 The Masonry Fireplace s Draft Control System Throat Damper 30 8 3 Compliance of a Combustible Mantel Shelf 31 8 4 Positioning the Unit 32 8 5 Minimum Masonry Opening Clearances to Combustibles and Floor Protector 36 9 The Venting System 38 9 1 General 38 9 2 Block Off Plate 38 9 3 Suitable Chimn...

Страница 5: ...e Optional Fresh Air Intake Kit AC01298 46 Appendix 3 Faceplate Installation 47 Appendix 4 Blower Replacement 49 Appendix 5 Installing the Optional Fire Screen AC01315 51 Appendix 6 Installation of Secondary Air Tubes and Baffle 52 Appendix 7 Removal instructions 54 Appendix 8 Exploded Diagram and Parts List 55 ENERZONE LIMITED LIFETIME WARRANTY 58 ...

Страница 6: ... NEVER USE GASOLINE LANTERN FUEL NAPHTHA FUEL OIL MOTOR OIL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS OR AEROSOLS TO START A FIRE IN THIS INSERT KEEP ALL SUCH LIQUIDS OR AEROSOLS WELL AWAY FROM THE INSERT WHILE IT IS IN USE DO NOT STORE FUEL WITHIN HEATER MINIMUM INSTALLATION CLEARANCES BURN ONLY SEASONED NATURAL FIREWOOD DO NOT BURN o GARBAGE OF ANY KIND o COAL OR CHARCOAL o TREATED PAIN...

Страница 7: ...ecommended heating area and maximum burn time may vary subject to location in home chimney draft heat loss factors climate fuel type and other variables The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure 1 Values are as measured per test method except for the...

Страница 8: ...andard EPA CSA B415 1 10 USA standard safety UL 1482 UL 737 Canadian standard safety ULC S628 East west through the door you see the longitudinal sides of the logs north south through the door you see the tips of the logs Mobile home Canada or manufactured home USA The US department of Housing and Urban Development describes manufactured homes better known as mobile homes as followed buildings bui...

Страница 9: ...Destination 2 3 Insert Installation and Operation Manual 9 ...

Страница 10: ...ving areas of your house to an adequate temperature we strongly recommend that you also have a conventional oil gas or electric heating system to provide backup heating Your success with zone heating will depend on several factors including the correct sizing and location of the insert the size layout and age of your home and your climate zone Three season vacation homes can usually be heated with...

Страница 11: ...re stainless steel which can also be recycled The C Cast baffle is made of an aluminosilicate fibre material that is compressed with a binder to form a rigid board C Cast can withstand temperatures above 2 000 F It is not considered hazardous waste Disposal at a landfill is recommended Firebrick is mainly composed of silicon dioxide also known as silica a product processed from a mined mineral It ...

Страница 12: ...nly spruce birch and poplar other low density species to burn and yet they can heat their homes successfully Homeowners with access to both hardwood and softwood fuel sometimes use both types for different purposes For example softer woods make good fuel for relatively mild weather in spring and fall because they light quickly and produce less heat Softwoods are not as dense as hardwoods so a give...

Страница 13: ...od dries more quickly when it is split Large unsplit rounds can take years to dry enough to burn Even when dried unsplit logs are difficult to ignite because they don t have the sharp edges where the flames first catch Logs as small as 3 75 mm should be split to encourage drying Wood should be split to a range of sizes from about 3 to 6 75 mm to 150 mm in cross section Having a range of sizes make...

Страница 14: ...s faster in dry weather than in damp maritime climates drying happens faster in warm summer weather than in winter weather small pieces dry more quickly than large pieces split pieces dry more quickly than unsplit rounds softwoods take less time to dry than hardwoods softwoods like pine spruce and poplar aspen can be dry enough to burn after being stacked in the open for only the summer months har...

Страница 15: ...er in weight than wet wood split a piece and if the fresh face feels warm and dry it is dry enough to burn if it feels damp it is too wet burn a piece wet wood hisses and sizzles in the fire and dry wood does not You could buy a wood moisture meter to test your firewood 3 3 Manufactured Logs Do not burn manufactured logs made of wax impregnated sawdust or logs with any chemical additives Manufactu...

Страница 16: ...t few fires the paint cures and the internal components of the insert are conditioned As the paint cures some of the chemicals vaporize The vapors are not poisonous but they do smell bad Fresh paint fumes can also cause false alarms in smoke detectors So when you first light your insert be prepared by opening doors and or windows to ventilate the house As you burn hotter and hotter fires more of t...

Страница 17: ...ional method first it does not collapse and smother itself as it burns and second it is not necessary to build up the fire gradually because the firebox is loaded before the fire is lit A top down fire can provide up to two hours of heating or more The top down method only works properly if the wood is well seasoned Start by placing three or four full sized split pieces of dry firewood in the fire...

Страница 18: ...rk or cooking and it can be warmer when you are inactive such as when reading or watching television Wood burns best in cycles A cycle starts when a new load of wood is ignited by hot coals and ends when that load has been consumed down to a bed of charcoal about the same size as it was when the wood was loaded Do not attempt to produce a steady heat output by placing a single log on the fire at r...

Страница 19: ...most of the combustion air enters the firebox and where they can ignite the new load quickly and second the charcoal will not be smothered by the new load of wood If you were to simply spread the charcoal out the new load will smoulder for a long time before igniting Remove ash first and then rake charcoal towards the front of the firebox before loading so that it will ignite the new load 4 4 4 Fi...

Страница 20: ...re hot you can begin to reduce the air supply for a steady burn As you reduce the air supply to the fire two important things happen First the firing rate slows down to spread the heat energy in the fuel over a longer period of time Second the flow rate of exhaust through the insert and flue pipe slows down which gives more time for the transfer of heat from the exhaust You will notice that as you...

Страница 21: ...es of firewood and load them crisscross in the firebox The pieces should be only 3 to 4 in diameter After raking the coals you can lay two pieces parallel to each other corner to corner in the firebox and lay two more across them in the other direction Open the air control fully and only reduce the air after the wood is fully flaming This kind of fire is good for mild weather when you are around t...

Страница 22: ...ours 2 0 c f to 2 5 c f 6 to 8 hours 2 5 c f to 3 0 c f 8 to 9 hours 3 0 c f 9 to 10 hours Long burn times are not necessarily an indication of efficient insert operation When you are home during the day and able to tend the fire it is preferable to build a smaller fire that might provide three or four hours of heating than to fully load the firebox for a much longer burn Shorter burn cycles make ...

Страница 23: ...ool by wiping with a damp cloth or paper towel and then drying Never try to clean the glass when the insert is hot In spring and fall when the insert is run at lower temperatures you may see some light brown stains forming especially at the lower corners of the glass This indicates that the fire has been smoky and some of the smoke has condensed on the glass When the weather is mild you may find t...

Страница 24: ...k past it You can test the condition of the door gasket by closing and latching the door on a strip of paper Test all around the door If the paper slips out easily anywhere it is time to replace the gasket Use the correct replacement gasket that you can purchase from your retailer The diameter and density of the gasket is important to getting a good seal Place the door face down on something soft ...

Страница 25: ...de up Stick the end of the gasket to the middle of one edge then press the edge of the glass down onto the gasket taking care that it is perfectly centred on the gasket Peel off more of the backing and rotate the glass and press the next section onto the gasket Do not stretch the gasket as you place it Continue until you get to the start and trim the gasket to length Now pinch the gasket to the gl...

Страница 26: ...ring smoky fires can quickly cause a thick layer of creosote to form When you avoid smouldering so the exhaust from the chimney is mostly clear creosote builds up more slowly Your new insert has the right characteristics to help you to burn clean fires with little or no smoke resulting in less creosote in the chimney 5 2 2 How Often Should You Clean the Chimney It is not possible to predict how mu...

Страница 27: ...brushes The brush is forced up and down inside the chimney flue to scrub off the creosote The chimney should be checked regularly for creosote build up Inspection and cleaning of the chimney can be facilitated by removing the baffle CAUTION OPERATION OF YOUR DESTINATION 2 3 WITHOUT THE BAFFLE MAY CAUSE UNSAFE AND HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY NOTE Before installing th...

Страница 28: ... the owner s manual must specifically prohibit the installation of a fireplace insert When in doubt check with the fireplace manufacturer The installation of the zero clearance fireplace MUST be thoroughly inspected by a qualified person to ensure that it still meets the manufacturer s specifications The chimney must be at least 1 25 mm larger in diameter than the stainless steel liner that will r...

Страница 29: ...SONRY CHIMNEY AND MASONRY FIREPLACE CONFORMING TO BUILDING CODES FOR USE WITH SOLID FUEL DO NOT REMOVE BRICKS OR MORTAR FROM THE EXISTING FIREPLACE WHEN INSTALLING THE INSERT 7 2 Regulations Covering Insert Installation When installed and operated as described in these instructions the Destination 2 3 wood insert is suitable for use in residential installations The Destination 2 3 wood insert is n...

Страница 30: ... order to have a safe and compliant installation In addition you will find information about your insert model serial number etc You can find the certification label on the side towards the front of the outside of the air jacket of the insert To access the certification label the faceplate may need to be removed Therefore we recommend that you note the insert s serial number on this manual since i...

Страница 31: ...ensions are listed in the following table However no combustible mantel shelf can be installed at less than 19 5 8 498 mm above the top of cast iron faceplate of the insert If the depth of the mantel shelf is not listed in the table below add 11 5 8 295 mm to the depth of your mantel shelf to obtain the safe positioning of your mantel shelf For example for a 9 229 mm mantel shelf the safe position...

Страница 32: ...h extension is large enough If the value D is positive you will need floor protection in front of the hearth extension at least equivalent to the result D Here is a sample calculation to determine the need to add a non combustible materials floor protection For someone living in the USA whose insert would protrude 4 76 mm into the room C the calculation would be Value D B A C Value D 16 16 4 Value...

Страница 33: ...r of the floor protection First by adding the R values of materials used or by the conversion if the K factor and thickness of the floor protection are given To calculate the total R factor from R factors of the materials used simply add the R values of materials If the result is equal to or greater than the R value requirements the combination is acceptable To know the R values of some selected m...

Страница 34: ...950 Mineral wool insulation 0 320 3 120 Limestone 6 5 0 153 Ceramic board Fibremax 0 450 2 2 Horizontal still air 1 8 0 135 0 920 Information as reported by manufacturers and other resources For a 1 8 thickness You cannot stack horizontal still air to accumulate R values you must separate each layer of horizontal still air with another non combustible material The standard configuration of the ins...

Страница 35: ...with fireplace facing MILLIMETRES CAN 457 mm USA 406 mm 0 mm D B A C 356 mm Note If the installation requires the use of the projection kit AC01323 refer to the table below MAXIMUM EXTENDED A B Note 1 C D E AIR JACKET INCHES Dimension of the hearth extension CAN 18 USA 16 2 4 D B A C 10 12 Back from fireplace facing 2 or 4 51 or 102 mm MILLIMETRES CAN 457 mm USA 406 mm 51 102 mm D B A C 254 305 mm...

Страница 36: ...36 Destination 2 3 Insert Installation and Operation Manual 8 5 Minimum Masonry Opening Clearances to Combustibles and Floor Protector 5 127 mm 5 127 mm ...

Страница 37: ...d a minimum of 4 to the width of the minimum masonry opening If projection kit AC01323 sold separately is used L 17 5 8 or 15 5 8 If installed without projection kit L 19 5 8 Note 1 From door opening The depth of the hearth extension in front of the insert is included in the calculation of the floor protector s dimensions The masonry hearth should be at least 5 127 mm higher than the combustible f...

Страница 38: ...ock Off Plate To reduce the possibility of a cold air draft from the masonry chimney to get into the room when the insert in not working the installation of a sheet metal block off plate A in the drawing below is recommended Once you have made the block off plate to the proper dimension cut the pipe hole slightly larger than the liner s diameter and then install the liner through this hole Set the...

Страница 39: ...imney liner rigid or flexible to ensure satisfactory performance To ensure an optimal draft we also strongly recommend adding a minimum of 12 rigid liner between the top of the masonry chimney and the rain cap In all cases liners should be installed in accordance with the liner manufacturer s instructions including instructions for extension above the masonry Use Listed Chimney Liners UL 1777 CAN ...

Страница 40: ...chimney liner Follow the chimney liner starter adapter manufacturer s instructions In order to connect the chimney liner starter adapter to the flue outlet you can install the brackets with the screws that are in the owner s manual kit Using a powered driver secure the three brackets with the three screws provided 30131 on top of the insert in the three holes in front of the flue outlet The long e...

Страница 41: ...xhaust gases and may result in smoke roll out from the insert when it s door is opened for loading Only use an offset adaptor if a there is no other alternative and b if the total height of the fireplace and chimney is at least 20 feet If you must install a liner offset adapter secure the three brackets with the three screws provided 30131 on top of the insert in the three holes in front of the fl...

Страница 42: ...e warm air in the house is buoyant so it tends to rise This tendency of warm air to rise creates a slight pressure difference in the house Called stack effect it produces a slightly negative pressure low in the house relative to outside and a slightly positive pressure zone high in the house If there is no fire burning in a heater connected to a chimney that is shorter than the warm space inside t...

Страница 43: ...is not affected by wind pressures on the house Contrary to commonly expressed concerns almost all tightly sealed new houses have enough natural leakage to provide the small amount of air needed by the insert The only case in which the wood insert may not have adequate access to combustion air is if the operation of a powerful exhaust device such as a kitchen range exhaust causes the pressure in th...

Страница 44: ...f this feature 1 Remove the latch and hinge access plate A by unscrewing screws B 2 Remove the latch D and reinstall the screws that were securing the assembly into the holes Note To avoid dropping the door due to its weight get help from another person to perform the following steps 3 Remove screws C securing the hinges to the firebox 4 Rotate the door over 180 degree and secure the hinges on the...

Страница 45: ...he washer Q 3 Remove the door handle M rotate it a half of a turn and reinstall it in the same location Put back the spacers B 4 Attach the door handle M and washer Q on the handle guide P with the shoulder screw O Make sure the parts are properly assembled 5 Screw the nut N to secure the mechanism 6 Reinstall the handle guide P with the 2 bolts A To adjust the tightness of the door with spacers B...

Страница 46: ...s remove the rectangular knock out plate A located on the left or right side of the convection air jacket Choose the side that is best for your installation Then install the fresh air kit adapter B using 4 screws C Secure the flexible pipe E part AC02090 not supplied to the adapter B using one of the adjustable pipe clamps D Secure the other end of the pipe to the outside wall termination F using ...

Страница 47: ...AC01332 must be purchased separately to secure the projection kit to it Remove the faceplate parts of the packaging and inspect its content Then remove the wing nut that secures the blower switch assembly to the floor of the convection air jacket for transport The faceplate installation requires a ratchet and 3 8 box to secure each part to the front of the insert The back of each faceplate part is...

Страница 48: ...Operation Manual 3 Align the holes in the support bracket of faceplate F then tighten the screws H already installed on the insert 4 Align the holes in the support bracket of faceplate G then tighten the screws H already installed on the insert ...

Страница 49: ... Replacement 1 Slightly loosen screws B 2 Lift the faceplate A by then pull it towards you to remove 3 Slightly loosen the 4 wing nut C then pull the blower assembly D towards you to remove it from the convection air jacket Make sure to disconnect the wiring as it is accessible ...

Страница 50: ...50 Destination 2 3 Insert Installation and Operation Manual ...

Страница 51: ...he door opening Lean the upper part of the fire screen against the top door opening making sure to insert the top fire screen brackets behind the primary air deflector as in DETAIL A Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening Warning Never leave the stove unattended while in use with the fire screen ...

Страница 52: ... the left end of the tube into the rear left channel 2 Align the notch in the left end of the tube with the key of the left air channel hole Using a Wise grip hold the tube and lock it in place by turning the tube as shown in DETAIL A Make sure the notch reaches the end of the key way 3 Repeat steps 1 and 2 for the two tubes in the back then install the baffle before installing the two front tubes...

Страница 53: ...ir tubes A can be replaced without removing the baffle board B Important Notes The air tubes are identified for placement as follows Model Type of tube Destination 2 3 insert Front 30 holes of 0 147 Middle front 30 holes of 0 136 Middle rear 20 holes of 0 128 Rear 15 holes of 0 128 ...

Страница 54: ...instructions Remove the faceplate assembly A using the reverse steps of Appendix 3 If installed take off the backing plates B and C and the projection kit by removing the front screws securing them to the insert Remove the screws that secure the chimney liner to the fixation brackets E Unscrew the leveling bolts F located on each side of the insert Pull out the insert from the fireplace opening to...

Страница 55: ...Destination 2 3 Insert Installation and Operation Manual 55 Appendix 8 Exploded Diagram and Parts List ...

Страница 56: ...PLATE BACKING PLATE 1 10 AC01333 50 X 6 BOTTOM FACEPLATE BACKING PLATE 1 11 AC01322 29 X 44 FACEPLATE BACKING PLATE KIT 1 11 AC01332 29 X 50 FACEPLATE BACKING PLATE KIT 1 12 AC01323 PROJECTION KIT FOR INSERT 2 OR 4 1 13 30765 WOODEN DOOR HANDLE 1 14 30123 SCREW 8 32 X 5 8 PAN QUADREX ZINC 2 15 30766 WOODEN CAP HANDLE 2 16 SE24237 CAST IRON DOOR WITH GASKET AND HANDLE 1 17 AC09164 HANDLE MECHANISM ...

Страница 57: ...5 TANGENTIAL BLOWER 1800 115V 60hZ 30W S 90 CFM 1 50 PL65746 BLOWER BOTTOM FIXATION PLATE 1 51 40007 BLACK 1 X 1 8 X 1 SELF ADHESIVE GASKET 3 52 30484 WING NUT 1 4 20 4 53 PL65626 BLOWER WIRE GUIDE 1 54 30413 SNAP BUSHING 1 55 30417 BLACK HEX NUT 8 32 1 56 44028 CERAMIC THERMODISC F110 20F 1 57 30239 MECHANICAL SCREW 8 32 x 3 8 QUADREX ZINC 1 58 PL65627 JUNCTION BOX 1 59 60013 POWER CORD 96 X 18 3...

Страница 58: ...nvestigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall in no event be responsible for any uncommon indirect consequential damages of any nature which are in excess of the original purchase price of the product A one time replacement l...