6
FREESTANDING INSTALLATION
BIO-35 FREESTANDING PELLET STOVE
Width: 22 1/2”
Height: 29”
Depth: 24 1/2”
Weight: 185 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 35 lbs.
(This can vary slightly depending on pellet size, length, and diameter)
EPA status: exempt
Burn rate: 1.3 lbs to 4.1 lbs. per hour
BTU range: 8,200 to 35000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional
PREPARATION
Factory packaging must be removed, and some minor assembly work is
required prior to installation:
•
The door overlay must be installed on the door frame;
•
The louver kit must be installed in front of the heat exchanger;
•
The black knob must be attached to the heat exchanger rod;
•
The pedestal kits must be assembled to the body (freestanding
version);
•
The faceplate kit must be assembled to the body (insert version);
•
Filters may be inserted between the finger guards and the
convection blowers (see “filters assembly” section).
NOTE: The detailed instructions required to assemble the pedestal kit or
faceplate kit are supplied with the corresponding kit. Normally, your dealer
will perform these functions.
1-
Remove the three screws
2-
Remove the plate
3-
Put the three screws back
4-
Use the ash dump cap provided with the stove
CLEARANCES
The BIO-35 has been tested and listed for installation in regular and mobile
homes.(refer figure 1 & 2)
FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The
stove must be placed on a continuous (grouted joints) non-combustible
material such as ceramic tile, cement board, brick, 3/8” millboard or
equivalent, or other approved or listed material suited for floor protection.
NOTE: ceramic tile, or any tile, must be laid on a continuous non
combustible sheet to prevent the possibility of embers falling through to the
combustible floor if cracks or separation should occur in the finished
surface, this also applies to floor protection for Built-in raised hearths.
Check local codes for approved alternatives.
Clearances are measured from the sides, back and face (door opening) or
stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
3"
SI
DE
WA
LL
6"
2" *
BACK WALL
Figure 1
Back wall installation
ADJACENT WALL
2"
ADJ
ACEN
T WA
LL
2"
3"
3"
Figure 2
Corner installation
6"
6"
6"
Figure 3
Floor protection