7
MODEL: EWC612-1
USER’S MANUAL
16. LED STATUS INDICATOR TABLE
LED
STATUS
DESCRIPTION
Power LED
Red
ON
Indicates AC power is ON
Red
Flashing
Indicates AS power is ON and no Battery has been detected. ECO Mode.
LED
STATUS
DESCRIPTION
Charge LED
Orange
Flashing Fast
Qualification and battery condition check
Orange
Flashing Fast
Battery rejuvenation
Orange
Flashing Fast
Soft start charging
Orange
ON
Bulk charging or absorption charging
LED
STATUS
DESCRIPTION
Charged / Error LED
Green
ON
Battery is fully charged and is in Float/Maintenance mode
Green
Flashing
Battery analysis has failled
Red
ON
Short circuit or reverse polarity
Red
ON
Soft start charging timed out if Orange Charging LED is also flashing fast
Red
ON
Bulk charging timed out if Orange Charging LED is also flashing slow
Note:
When the unit is in ultra low power consumption mode (ECO Mode), this will be indicated
by the Power LED flashing RED. The unit will automatically go into this mode if no battery is
detected or connected.
17. CHARGING CURVE
Voltage
(VOLTS)
Current
(AMPS)
QUALIFICATION
Checks battery
condition to
determine whether
the rejuvenation
stage or charge
cycle is required.
REJUVENATION
Automatic stage
for batteries in poor
condition. Breaks
down sulphation
using new patented
techologie.
SOFT START
Increases your
battery life by gently
starting to charge
the battery until
the battery reaches
a set voltage.
BULK CHARGE
Reduces charging
time by delivering
maximum charge
until the battery
reaches a set
voltage.
ABSORPTION
Uses constant
voltage and
ensures the battery
receives a full
charge without
overcharginf the
battery.
ANALYSIS
Check the
battery condition
to ensure it's
fully charge.
FLOAT
Maintains the
battery at 100%
charge.
MAINTENANCE
Special pulse
charge for
long-term
maintenance to
ensure the battery
is in optimal
condition.
PROCESSUS DE CHARGE/DE MAINTIEN