SOLARDRIVE
PLUS
PROGRAMMING
GUIDE
26
/
107
2.2.15.
Keypad Page and Local Mode
keypad
+
0 . 0 H z
+ 0 . 0 A
5 5 0 v
+ 0 . 0 0 r p m
Keypad Help
M 0 0 6
M o t . F r e q .
M 0 2 6
I ( R M S ) O u t
M 0 2 9
V b u s - D C
M 0 0 4
M o t o r
S p d
To access the Keypad pages, press the
MENU
key
from the Root Page or press the
LOC/REM key
after
selecting the Local mode.
The measures displayed on the Keypad page can be set up through parameters
P268b
to
P268e
. From the
Keypad page, press the
SAVE/ENTER
key to display the Keypad Help page, describing the measures
displayed on the Keypad page. The Keypad Help page is displayed for a few seconds.
As default, there are displayed:
Output frequency (measure
M006
)
Output current (measure
M026
)
DC bus voltage (measure
M029
)
Motor speed (measure
M004
)
NOTE
If parameter P264b (Navigation mode via MENU key) is set to Operator, navigation is locked
once the Keypad Page is displayed. Hold down the ESC key for a few seconds to resume
navigation
The following Keypad Pages are available:
Measures only
four lines displaying measures only
Speed
line 4 shows the speed reference, that can be changed with the
▲
and
▼
keys.
If the Local Mode is NOT selected, pressing the MENU key allows viewing only the pages containing the
references sent via keypad (See Control Method Menu, section 2.6.6).
LOCAL MODE
In
LOCAL
mode (the L-CMD and L-REF LEDs come on when the Local mode is active), only the commands
and references sent via keypad are enabled, while any other control source or reference source is disabled
(see Control Method Menu, section 2.6.6). The keypad page displayed when the
LOC/REM
key is pressed is
as follows:
+
0 . 0 H z
+ 0 . 0 A
5 5 0 v
R e f
+ +
0 . 0 0 r p m
Use the
▲
and
▼
keys to change the reference shown in line 4 on the Keypad Page.