Manual
Operation Manual for
ZeMa Single Cells
Prepared on: 23-11-2022
Prepared by: GBA
Released on: 04.01.2023
Released by: -
Revised on: -
Index: _-
Distributed to: customer (public)
Pages: 7/35
This document is uncontrolled when printed. For the most current and official copy, check the server.
Rail Engineering
Tel. +49 (0) 2331/372 591
Dieckstrasse 42
Fax +49 (0) 2331/372 804
DE-58089 Hagen
www.enersys.com
3.
Product description
3.1
Rolling Stock Single Cells
These Instructions are valid for the following VLRA AGM Single Cells:
•
ZeMa200P18
•
ZeMa270P12
•
ZeMa340P12
•
ZeMa450P21
3.1.1 Common Technical Data of the rolling stock single cells
ZeMaXXPxx
Technology
: VRLA (AGM), TPPL+Sn
Nominal Voltage
: 2 V
Flame retardant battery case : PC+ABS FR or Estaprop, halogen free
V-0 (UL 94), I3 / F2 (NF F 16-101)
Shock and Vibration
: Category 1, Class B (EN 61373)
The single cells are delivered charged and ready for use.
3.1.2 Technical Data: Rolling Stock Single Cells
ZeMa200P18
Rated Capacity
: 208 Ah C
10
Part number
: SR70770206
Dimensions (WxDxH)
: 125 x 157 x 259 mm
Terminals
: M10 x 20 deep, female thread
Weight
: 14.5 kg ±2%
For more technical data take reference to the data sheet:
•
Hawker_ZeMaRail_ZeMa200P18_Brochure_01_EN_2021-03-V2.pdf
3.1.3 Technical Data: Rolling Stock Single Cells
ZeMa270P12
Rated Capacity
: 270 Ah C
10
Part number
: 1896504V0CP
Dimensions (WxDxH)
: 83 x 198 x 370 mm
Terminals
: M10 x 22 deep, female thread
Weight
: 16.3 kg ±2%
For more technical data take reference to the data sheet:
•