20.1.2 Mild Corrosion Cleaning
To clean mild corrosion from the battery:
1.
Remove safety shields.
2.
Remove corrosion by wiping with a cloth dampened with bicarbonate of soda solution
[mix 1 gallon (4 l) of water with 1 lb. (500g) of bicarbonate of soda]. Follow with a cloth
dampened with clean water.
3.
Dry with a clean cloth.
20.1.3 Terminal Rework
If a terminal connection needs to be reworked (for any reason) follow the steps below:
1.
Disconnect the battery from load.
2.
Remove safety shields.
3.
Unbolt and remove connectors.
4.
Apply a solution of bicarbonate of soda and water to the cell posts and connectors to
neutralize the corrosion (as described in Section 20.1.2).
5.
Clean the contact surfaces by rubbing the surface of post or terminal and lead-plated
or tin-plated contact surfaces with a stiff-bristle nonmetallic brush/scotch brite type
pad. Lightly brush tin plated connectors. Exercise care so you
do NOT remove
the plating on the connectors, terminal plates or lugs, exposing copper.
6.
Apply a thin coating of NO-OX-ID type grease to the contact surfaces.
7.
Bolt all inter-cell connectors. Install as follows (Refer to Figure 17 in Section 13.1):
a. Bolt
c. Connector
e. Connector
g. Lock Washer
b. Flat Washer d. Battery Terminal
f. Flat Washer
h. Hex Nut
WARNING
STAMPED FLAT WASHERS MAY HAVE ONE SHARP EDGE. INSTALL THE WASHER WITH THE SHARP
EDGE AWAY FROM THE INTER-CELL CONNECTOR TO AVOID DAMAGING THE PLATING.