background image

CAUTION 

 
Operating the charger from 
230 VAC while switched for 
115 VAC will permanently 
damage the charger 
transformer and the charger 
will need to be replaced. 

 
 

OPERATION / 
MAINTENANCE 

 
 

OPERATION 

 
1. Any battery must be 

recharged - regardless 
of how long it has been 
used - before next use 
in order to maintain the 
battery’s rated capacity 
and cycle life. Typically, 
the approximate 
recharge time is 8 hours 
after an 8-10 hour 
discharge. Longer 
recharge times can be 
expected if longer 
discharge times are 
used. 

After connection of the cap 
lamp, the red LED will 
illuminate after a short time, 
the circuitry will wait 5 
seconds then start the 
constant current charge 
(stage 1) while monitoring 
the charger voltage.  When 
the charging voltage 
reaches 5.3 VDC the 
charger switches to a 
constant potential of 5.1 
volts (stages 2 & 3) for a 
set period of time (full 
charge is reached when the 
green LED is on only), the 
charger then switches to a 
'‘float’’ mode voltage of 4.6 
volts (stage 4) until the 
battery is removed.  The 
battery state of charge is 
indicated by the Charge 
Indicator Guide. 

 
 
 
 
 

 
 

Note: 

 

 

 

If the battery is removed or 
input power is interrupted, 
the charger will reset to 
stage 1 when reconnected.  
The charger will quickly 
read the level of charge in 
the battery then go on to 
the appropriate stage 
where it left off before the 
interruption.  It is not 
advisable to leave a battery 
partially discharged for any 
extended length of time. 

 

Doing so will reduce the 
cycle life and capacity of 
the battery. 

 
 
 

 
 
2.  Plug the charger into an 

appropriate power 
supply. The yellow LED 
on the front panel 
indicates that the input 
power supply is “on”. 

 
 
3. To charge the cap 

lamp, the headpiece 
should be fitted over the 
projecting key on the 
front of the charger and 
rotated clockwise until it 
is in the full stop 
position.  To remove the 
lamp from charge – 
reverse the procedure. 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stage

LED Display

Charge Status

1. Constant Current Mode

RED light on

charging

2. Constant Potential Mode

RED and GREEN light on

75% charged

3. Fully Charged

GREEN light on

fully charged, ready for use

4. Float Mode

GREEN light on, RED light flashing

float charge mode; ready for use

Charge Indicator Guide

Отзывы: