D. TORQUE SPECIFICATIONS
Each terminal type has a different torque specification. Under-tightening of connections can lead to
short circuit and electrical damage. Over-tightening can cause physical damage to the battery
terminal. Refer to Table 2 below for the recommended torque specification based on the terminal type.
V. TECHNICAL DETAILS
A. OPERATING TEMPERATURE RANGE
Temperature impacts the life and performance of AGM
2
batteries, as it does all batteries. In general,
higher temperatures reduce battery life while lower temperatures reduce the available capacity that a
battery can provide. Refer to Table 3 below for the operating temperature range for each model.
Terminal Type
Details
Maximum Torque
[in-pounds]
Maximum Torque
[Nm]
Stud 3/8-16” HD
All G31, Marine, and 8D
200
22.6
Stud 3/8-16”
ODS-AGM6M
100
11.3
Stud 5/16-18”
All Marine
100
11.3
Side Terminal 3/8-16” Receptical
G75 G78
60
6.8
M4 Receptacle
ODS-AGM8E (PC310)
8.9
1
M6 Receptacle
ODS-AGM16B,16CL
40
4.5
M6 Receptacle
ODS-AGM15L, 16L
50
5.6
M6 Receptacle
ODS-AGM28*,42*,70*
60
6.8
M6 Receptacle
ODS-AGM***FT
35
3.9
* For SAE torque specification refer to vehicle manufacturer’s specification.
Battery Model
Maximum Operating Temperature Range
ODP-AGM
All Models
-40°F (-40°C) to 140°F (60°C)
Except ODP-AGMDIN sizes
(with or without ACE)
-40°F (-40°C) to 113°F (45°C)
ODX-AGM
All Models
-40°F (-40°C) to 176°F (80°C)
ODS-AGM
Powersports (without metal jacket)
-40°F (-40°C) to 113°F (45°C)
Powersports with metal jacket
-40°F (-40°C) to 176°F (80°C)
Marine and RV
-40°F (-40°C) to 104°F (40°C)
NSB-AGM
All Models
-40°F (-40°C) to 176°F (80°C)
Table 2
Table 3