background image

3

Instructions for use Hawker

®

 Life IQ

TM

 Modular

ENGLISH

SAFETY INSTRUCTIONS

 AIM OF THIS MANUAL

This manual  is designed for use by any skilled worker 

wishing to use Hawker

®

 Life IQ

TM

 Modular battery chargers 

for recharging lead/acid vented, (with or without electrolyte 

mixing), valve regulated AGM and gel batteries.

This manual provides details of:

•  The chargers’ functions.

•  Any adjustments required and how to use the chargers.

When producing this manual, EnerSys

®

 has aimed to provide  

its information in as simple and precise a manner as 

possible but cannot assume any responsibility for any 

misinterpretation. The owner of the equipment is required to 

retain this manual throughout the equipment’s life and to pass 

it on to any purchaser in the event of its resale.

The manufacturer covers the guarantee in accordance with 

the local regulations (contact local sales organization).

Recommended use

This manual should be read through carefully before using 

the equipment and also read by anyone likely to use the 

equipment. 

The equipment:

•   Presents no obstacles to the free circulation of air through 

the air inlet and outlet but, nevertheless, should be cleaned 

of dust every six months by a qualified person.

•   Must be used in conformance with its indicated level of 

protection and never come into contact with water.

•   Must be used within the temperature limits stated in the 

technical characteristics.

•   Must not be installed on surfaces subject to vibration (near 

to compressors, engines, motors).

Operator safety

Take all necessary precautions when the equipment will 

be used in areas where there is the possible risk of an 

 

accident occurring. Ensure appropriate ventilation according to  

reference standard EN50272-3 (in addition to any local 

regulations) to allow any gases released to escape. Never 

disconnect the battery while it is being charged.

 ELECTRICAL SAFETY

The prevailing safety regulations must be observed. The 

system protection installed on the power supply to the charger 

must conform to the charger’s electrical characteristics. The 

installation of a suitable circuit breaker is recommended. It is 

imperative to ensure that when fuses are being replaced only 

fuses of the specified type and of the correct  are used. It is 

strictly forbidden to use inappropriate fuses or to short-circuit 

the fuse holders. This equipment conforms to Class 1 safety 

standards, which means that the appliance must be earthed 

and requires to be powered from an earthed supply.

Never open the equipment:

 High voltage could be still present 

even after turning off the charger.

Any adjustment, maintenance or repairs to the equipment 

while it is open must only be carried out by an appropriately 

skilled person who is aware of the risks involved.

Contact one of the company’s trained technicians if any 

problem is encountered when putting the charger into 

operation.

This equipment has been designed for indoor use. It is only 

designed to recharge lead/acid batteries on industrial premises.

When the equipment becomes obsolete, the casings and the 

other internal components can be disposed of by specialist 

companies. Local legislation takes precedence over any 

instructions in this document and must be scrupulously 

observed (WEEE 2002/96 EC).

EnerSys reserves the right to make any improvements and/or 

modifications to the product described in this manual at any 

time and without prior notice and is not obliged under any  

circumstances whatsoever to update the contents of this 

 

manual nor the equipment concerned.

The equipment’s production number must be supplied when 

requiring a service.

If the charger is to be stored before its use, it must be  

kept carefully sealed in its original packaging. It must be 

stored in a clean and dry location at a moderate temperature 

(-20°C to +40°C). Equipment stored at a temperature of 

 

less than 15°C must be brought progressively to operating  

temperature (over a period of 24 hours) to avoid any risk of  

condensation causing electrical faults (particularly short-

circuits).

 EC DECLARATION

EnerSys hereby declares that the chargers in the  

Life IQ Modular range covered by this declaration  

conform to the descriptions laid down in European 

Directives:

2004/108/EC:

EN61000-6-2, EN61000-6-4: Immunity and emissions limits for 

industrial electronics

2006/95/EC:

EN60950, EN60335 (Low Voltage Directive)

RoHS 2011/65/EC

AS 2548.1-1998

RCM (C TICK)

CEC

Отзывы: