background image

The manual describes the processes for trained technicians to maintain Hawker

®

 sealed lead acid batteries as defined 

in appendix A, and covers their basic design features, maintenance, storage, transportation and ultimately the disposal 
requirements of the battery.

Only trained staff should have access to the manual, which always shall be of latest revision and kept in good condition 
by the battery owner.
 

The Hawker

®

 battery is a valve regulated lead acid (VRLA) 

system, using absorbed glass mat (AGM) to retain the 
electrolyte. The battery operates on the principle of gas 
recombination resulting in minimal gas evolution during 
normal operation. The battery is fully compatible for use 
on aircraft, which may perform aerobatic manoeuvres.

The battery is maintenance free with respect to electrolyte 
replenishment. Under no circumstances should any 
attempt be made to interfere with construction or 
introduce any substances, e.g. acid, distilled water or 
alkali, to the battery.

The Hawker

®

 24 volt aircraft battery covered by this 

maintenance manual consist of two 12 volt valve 
regulated monoblocs connected in series, enclosed in a 
polyester bonded fibreglass case which incorporates the 
battery main terminal connector. The monobloc design 
is based upon a Thin Plate Pure Lead (TPPL), valve 
regulated, lead acid system.

Each 12 volt monobloc consists of six 2 volt cells 
internally connected in series to make a 12 volt block. 
The individual 2 volt cells are not replaceable. The cells 
within the monoblocs are interconnected with through-
the-partition-wall weld connections.

The cells are manufactured with proprietary VRLA AGM 
technology that can deliver high performance engine start 
capability in excess of 50C

1

 amps at normal temperature 

and superb durability under emergency load conditions.

Thin fiberglass separators are placed between the 
positive and negative plates. The tightly packed 
plates and separator form a compressed and rugged 
construction, which enhances the battery’s resilience to 
vibration.

1.

 SCOPE

4

2.

 INTRODUCTION

3.

  BATTERY DESCRIPTION

Содержание HAWKER 9250-0083

Страница 1: ...AEROSPACE Sealed Lead Acid Batteries Aircraft Battery Maintenance Manual UK Sealed Lead Acid Batteries Aircraft Battery Maintenance Manual UK...

Страница 2: ...TANT Please read this manual immediately on receipt of the battery ies before unpacking and installing Failure to comply with these instructions will render any warranties null and void to the extent...

Страница 3: ...SPECTION 9 8 2 VOLTAGE CHECKS 9 9 CHARGING PROCEDURE 10 10 ROUTINE MAINTENANCE 10 11 SERVICE PERIOD 11 12 CAPACITY TEST 11 13 REJECTION PROCEDURE 12 14 DEEP DISCHARGE RECOVERY 12 15 UNSCHEDULED REMOVA...

Страница 4: ...id distilled water or alkali to the battery The Hawker 24 volt aircraft battery covered by this maintenance manual consist of two 12 volt valve regulated monoblocs connected in series enclosed in a po...

Страница 5: ...ately Clothing contaminated by acid should be washed in water Electrolyte is highly corrosive In the normal operation of this battery contact with acid isn t possible If the cell containers are damage...

Страница 6: ...ampere discharge for 1 hour down to a battery voltage of 20 volts By conventional definition the battery is deemed airworthy if it delivers its rated capacity for 48 minutes down to a voltage of 20 vo...

Страница 7: ...administered in accordance with paragraph 9 However it is advisable to conduct an inspection and open circuit voltage check after 12 months and top up charge in accordance with paragraph 9 if necessar...

Страница 8: ...rity Nominal battery voltage and number of cells Rated capacity Safety instructions where applicable Warning Short circuit currents will exceed 2000 amps all tools must be insulated Care must be taken...

Страница 9: ...ttery can be issued for service 8 2 4 If the OCV is equal to or less than 25 3 volts but greater than 20 0 volts the battery needs to be charged 8 2 4 1 Charge the battery in accordance with paragraph...

Страница 10: ...he exterior of the battery casing for signs of damage and cracks Examine the battery terminal for signs of damage corrosion and water dirt ingress clean as necessary Always ensure that the battery lid...

Страница 11: ...one hour rate and measuring the time required in minutes to reach the cut off voltage Discharge the battery at the appropriate constant current value found in Figure 5 at 20 2 C to an end voltage of 2...

Страница 12: ...y in accordance with paragraph 9 and notify EnerSys or your distributor of failure If the battery has an OCV of less than 20 volts it is considered to have been abused Over discharging the battery to...

Страница 13: ...lass 8 Proper Shipping Name BATTERIES WET NON SPILLABLE electric storage Packing Group ADR not assigned Label required Corrosive ADR RID New and spent batteries are exempt from all ADR RID special pro...

Страница 14: ...ashers and metal strip laminations from the rear monobloc terminals e Remove and discard the nuts and washers from the front terminals and lift off the laminations Note Do not remove the front laminat...

Страница 15: ...ne maintenance or unscheduled maintenance vii Date of battery returned to storage viii Date of any failures ix Date of any returns to manufacturer x OCV prior to any discharge Dispose of the battery i...

Страница 16: ...V Elcon None 38 0 9750E0640 9750E0654 25Ah 24V Elcon None 27 0 9750E0645 25Ah 24V Elcon 1 27 0 9750E0647 9750E0652 25Ah 24V Elcon 1 27 0 9750E0650 25Ah 24V Spade None 27 0 9750E0658 25Ah 24V Canon 1 2...

Страница 17: ...e as per paragraph 13 0 Issue Battery Reject battery Charge battery as per paragraph 9 0 Charge battery as per paragraph 9 0 Charge battery as per paragraph 9 0 25 5 Volts 25 3 25 5 Volts 25 3 Volts 2...

Страница 18: ...attery as per paragraph 9 0 48 minutes Second time 48 minutes First time 48 minutes Capacity test as per paragraph 12 0 Stand for 4 hours Follow Rejection procedure as per paragraph 13 0 Reject batter...