COMPONENT MAINTENANCE MANUAL
BA27
24-01-01
T
h
is docum
ent
contains D
a
ta
control
led by th
e U.S. Export Admini
str
a
tion
Reg
u
lati
ons. Di
versio
n or use
contrary to U.S. law is
proh
ibit
ed
H Charging
Instructions
Charging of the Flight Controls battery should be performed using a constant
voltage charger, capable of constantly supplying 28.5 volts with a minimum supply
current of 10 amps. Using the set-up illustrated in figure 5. (Minimum charge time 6
hours)
U
NOTE:
U
If the battery fails the first charging test per TESTING section 4.I, during
the second charging test, charge the battery for 12-24 hours.
U
NOTE
U
:
Charging should be conducted between 20°C (68°F) and 30°C (86°F).
The battery capacity may vary if charged outside this recommended
temperature range.
Page 14