81
704-939-B10-001 Rev. A5 (06/2019)
9.0 Start Up and Verification
9.1 Initial Start Up and Local Verification
To confirm successful hardware installation before leaving the installation site, verify network connectivity and correct
hardware interconnection.
To Verify Network Connectivity:
The DS and REG LEDs on the front of the DM3X Transponder should be ON solid green. This indicates successful
registration with the headend. In addition, the RF LED should also be ON solid green indicating proper RF power levels
and the ALM/RDY LED should be blinking green for normal operation.
With the DM3X Transponder used in conjunction with the XM2 power supply, network connectivity can be verified via
the COMM menu on the XM2 LCD Display. Pressing ENTER while in the Operation Normal screen will open the Comms
Information display (only displayed when paired with suitable communications module, otherwise display will read “NO
DATA”). When accessing the information display, information displays in Auto Scroll mode. Press UP or DOWN to access
information one step at a time. Press ENTER to access the Setup Menu. Press ESCAPE to reactivate Auto Scroll mode.
Press ESCAPE a second time to reactivate Operation Normal mode (up one level)
The following provides a list of parameters available on the XM2 LCD Display COMMS Menu populated with sample
values.
Fig. 9-1, XM2 Smart Display Screens
COMMS INFO
CM
CM
CM Rx PWR
CM Tx PWR
DN FREQ
UP FREQ
MODEL
SW
BATT
BATT
BATT
00:90:EA:00:30:54
192.168.1.151
-6.7dBMv
41.0dBMv
369.000Mhz
15.000Mhz
DM3X
4.5.9.0_00.77CO-N
A1 = 13.1 A2 = 14.0
A3 = 13.5 B1 = 13.1
B2 = 14.0 B3 = 13.5
OUTPUT
ALARM
TEST