7.0 Installation, continued
69
704-939-B10-001 Rev. A5 (06/2019)
7.4 Connecting the RF Drop
Connect the RF drop according to the diagram below. The RF drop must have a properly installed ground block in the
power supply enclosure. Recommended downstream RF level is 0 dBmV. Connect any other front panel connections at
this time (e.g. battery strings, tamper switch).
Install a grounded surge suppressor (Alpha P/N 162-028-10 or equivalent). Failure to install an
appropriate surge suppressor may void the warranty
CAUTION!
Grounded Surge
Protector
(See Caution Above)
RF Cable to
Headend
Fig. 7-5, Connecting the RF Drop
Alpha Technologies Services, Inc. recommends tightening the RF cable connector and the cables attached to the
Grounded Surge Protector to a torque setting of 10in-lb ± 1in-lb.
NOTICE
: