Enerpac SLCV-24 Скачать руководство пользователя страница 1

Hydraulic Technology Worldwide

Instruction Sheet

8-Point Synchronous Lift Controller

L2583

Rev. E

04/08

Table of Contents

Page

Important Receiving Instructions.........................................................2

Safty First - Safety Issues ...................................................................2

General Description /Glossary Of Terms Used ...................................3

Components Used ..............................................................................3

Electrical Specifications ......................................................................3

Selection Of Hydraulic Components ..................................................4

System Lifting/Lowering Speed ..........................................................4

Control Panel Switch Functions ..........................................................5

System Requirements .........................................................................5

Hydraulic Component Assembly.........................................................6

Basic 4 Point System Schematic ........................................................6

Electrical Component Assembly .........................................................7

System Power Up And Control Verification ...........................................7

A. Language................................................................................7

B. System Setup.........................................................................8

C. Lift Type ..................................................................................8

D. Cylinder Control Check ..........................................................9

E. Cylinder/Sensor Interface Check .........................................10

F. System Flow Control Valve Setting......................................10

Lifting Sequence..............................................................................10

System Error Messages ..................................................................11

Trouble Shooting Guide...................................................................11

Lowering the Load...........................................................................12

Index:

English:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12

Español: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NA

Portuguese:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NA

Содержание SLCV-24

Страница 1: ...4 System Lifting Lowering Speed 4 Control Panel Switch Functions 5 System Requirements 5 Hydraulic Component Assembly 6 Basic 4 Point System Schematic 6 Electrical Component Assembly 7 System Power U...

Страница 2: ...relief valve to a higher pressure than the maximum rated pressure of the pump Higher settings may result in equipment damage and or personal injury WARNING The system operating pressure must not excee...

Страница 3: ...AGE in some cases Consult Enerpac on specific recommendations HYDRAULIC PUMP The HYDRAULIC PUMP provides flow to the HYDRAULIC CYLINDERS allowing them to advance or retract The CONTROLLER operates the...

Страница 4: ...s 71 2 cm2 X 4 cylinders 284 8 cm2 The pump flow rate is 0 82 liters minute 50 hertz and 1 02 liters minute 60 hertz 820 cm3 and 1020 cm3 minute respectively 820 cm3 min 284 8 cm2 2 88 cm min 50 hertz...

Страница 5: ...Key Completes data entry sequence and exits data entry mode EXTEND RETRACT Selects extend or retract mode of cylinder MANUAL AUTOMATIC AUTOMATIC provides synchronous motion of all active cylinders MA...

Страница 6: ...k valve body connects to the advance port of the cylinder using the fitting provided The quick coupler in the cylinder advance port is removed and used in the PUMP port of the check valve body NOTE Th...

Страница 7: ...connection points 1 4 and so on 6 Place an SLSS SENSOR at each lift point Connect an SLSC 15 SENSOR CABLE between the SENSOR and the CONTROLLER The SENSOR placed at lift point No 1 must be connected t...

Страница 8: ...ect MANUAL UP Fig 8 4 Activate the cylinder for lift point 1 only 5 When the cylinder is moving the display will show a numeric value for that lift point You saw the same thing when you manually check...

Страница 9: ...stop the load and indicate the problem Figure 10 Automatic Down IMPORTANT Before proceeding further with the lift lower the load to its original position by switching to AUTO DOWN mode Fig 10 This sho...

Страница 10: ...NOTE System Inactive usually points to a load that is too heavy and cannot be lifted by some or all the cylinders 10 1 METHODS FOR CORRECTING CYLINDER TO CYLINDER ACCURACY ERRORS METHOD 1 The error ma...

Страница 11: ...OR for that lift point CAUSES AND CURES 1 Sensor cord has become disconnected from the load See sensor cord rapid retract caution page 13 fully extend then slowly retract cord to unscramble Reattach s...