Enerpac PATG Series Скачать руководство пользователя страница 1

1

Repair Parts Sheets for this product are available from the Enerpac 
web site at www.enerpac.com, or from your nearest Authorized 
Enerpac Service Center or Enerpac Sales offi

  ce.

1.0  IMPORTANT RECEIVING INSTRUCTIONS

Visually inspect all components for shipping damage. Shipping 
damage is not covered by warranty. If shipping damage is found, 
notify carrier at once. The carrier is responsible for all repair and 
replacement costs resulting from damage in shipment.

SAFETY FIRST

2.0  SAFETY ISSUES

Read all instructions, warnings and cautions 
carefully. Follow all safety precautions to avoid 
personal injury or property damage during system 

operation. Enerpac cannot be responsible for damage or injury 
resulting from unsafe product use, lack of maintenance or incorrect 
product and/or system operation. Contact Enerpac when in doubt 
as to the safety precautions and operations. If you have never 
been trained on high-pressure hydraulic safety, consult your 
distribution or service center for a free Enerpac Hydraulic safety 
course.

Failure to comply with the following cautions and warnings could 
cause equipment damage and personal injury. 

CAUTION

 is used to indicate correct operating or maintenance 

procedures and practices to prevent damage to, or destruction of 
equipment or other property.

WARNING

 indicates a potential danger that requires correct 

procedures or practices to avoid personal injury.

DANGER

 is only used when your action or lack of action may 

cause serious injury or even death.

WARNING:

 Wear proper personal protective gear when 

operating hydraulic equipment.

WARNING:

 Stay clear of loads supported by hydraulics. A 

cylinder, when used as a load lifting device, should never 
be used as a load holding device. After the load has been 

raised or lowered, it must always be blocked mechanically.

WARNING: USE ONLY RIGID PIECES TO HOLD 
LOADS.

 Carefully select steel or wood blocks that are 

capable of supporting the load. Never use a hydraulic 

cylinder as a shim or spacer in any lifting or pressing application.

DANGER:

 To avoid personal injury keep hands 

and feet away from cylinder and workpiece during 
operation.

WARNING:

 Do not exceed equipment ratings. Never 

attempt to lift a load weighing more than the capacity of 
the cylinder. Overloading causes equipment failure and 

possible personal injury. The cylinders are designed for a max. 
pressure of 700 bar [10,000 psi]. Do not connect a jack or cylinder 
to a pump with a higher pressure rating.

Never set the relief valve to a higher pressure than the 
maximum rated pressure of the pump. Higher settings 
may result in equipment damage and/or personal injury.

WARNING:

 The system operating pressure must not 

exceed the pressure rating of the lowest rated component 
in the system. Install pressure gauges in the system to 

monitor operating pressure. It is your window to what is happening 
in the system.

CAUTION: 

Avoid damaging hydraulic hose. Avoid sharp 

bends and kinks when routing hydraulic hoses. Using a 

bent or kinked hose will cause severe back-pressure. Sharp bends 
and kinks will internally damage the hose leading to premature 
hose failure. 

 

Do not drop heavy objects on hose. A sharp impact 
may cause internal damage to hose wire strands. 
Applying pressure to a damaged hose may cause it to 
rupture.

IMPORTANT:

 Do not lift hydraulic equipment by the 

hoses or swivel couplers. Use the carrying handle or 
other means of safe transport.

CAUTION:

 Keep hydraulic equipment away from 

fl ames and heat. Excessive heat will soften packings 
and seals, resulting in fl uid leaks. Heat also weakens 

hose materials and packings. For optimum performance do not 
expose equipment to temperatures of 65°C [150°F] or higher. 
Protect hoses and cylinders from weld spatter.

L2532 Rev. 

D 05/12

Index:

Figures 

図 

 

: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6-7

English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-5
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-12
Deutsch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13-17
Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18-22 
Español  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23-27 
Nederlands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28-32
Portuguese:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33-37

日本語

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38-42

汉语

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43-47

POWERFUL SOLUTIONS.  GLOBAL FORCE.

Instruction Sheet

10,000 PSI TURBO II AIR PUMPS

 

Содержание PATG Series

Страница 1: ...ct steel or wood blocks that are capable of supporting the load Never use a hydraulic cylinder as a shim or spacer in any lifting or pressing application DANGER To avoid personal injury keep hands and...

Страница 2: ...air pressure adjustment 5 2 Air Connections See Illustration 1 Attach air supply to the 1 4 NPT swivel connection on the end of the pump Use Teflon tape or similar thread sealant Torque to 20 25 ft l...

Страница 3: ...ll port pull up the vent fill assembly past the first detent Then completely remove the assembly from the reservoir If oil level is low add oil as described in Section 5 6 To use as a return to tank p...

Страница 4: ...e intake tube to refill the pressure chamber You may need to hold the treadle and throttle the PRESSURE button for a few minutes to completely remove the air and prime the pump models with an air pend...

Страница 5: ...but load does not move Load greater than cylinder capacity at full pressure Flow to cylinder blocked 6 Cylinder drifts back on its own External system leak Internal leak in system component 7 Cylinde...

Страница 6: ...igure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 7A Figure 7B Figure 8 6 A CLOSED Ferm Geschlosen Chiuso Cerrado VENTED A r Entl ftet Ventilazione Abierto 1 2 B A 8 8 4 4 3 3 2 2 1 1 7B 7B 7A 7A 5 5...

Страница 7: ...Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 7 1 2 C B A A 10 10 11 11 9 9 12 12 13 13...

Отзывы: