background image

1

2

INSTALLATION INSTRUCTIONS

3

WARNING

Turn the POWER OFF at the circuit breaker before installing the sensor

Read and understand these instructions before installing.  This device is 

intended for installation in accordance with the National Electric Code and local 

regulations.  It is recommended that a qualified electrician perform

s

 this 

installation.  Make sure to turn off the circuit breaker or fuse(s) and make sure 

power is off before wiring the device.

Use copper wires only. NEUTRAL WIRE IS REQUIRED.

WIRING DIRECTIONS

As illustrated in Figure 1, The DWHOS has a 180° detection range with a 

maximum distance of 24’ detection in front of the sensor

 and 

12

' on the sides

.  

For maximum results, the sensor must be properly installed between the height 

of 4’ to 5’ and away from obstructions such as walls, furniture and transparent 

barriers like Low-E glass.

DWHOS

Dual Technology Humidity/PIR Motion Sensor

Figure 1

Max. 

12

'

on the sides

Max. 

24

'

from front

Installation

Height: 4' - 5'

Detection Range

1. Connect RED wire from sensor to the LIGHT wire.

2. Connect BROWN wire from sensor to the FAN wire.

3. Connect BLACK 

AND

 BLUE 

wire from sensor to the HOT wire.

4. Connect WHITE wire from sensor to the NEUTRAL wire.

5. Connect GREEN wire from sensor to the GROUND wire. 

Power..............................................................................................120VAC, 60Hz

Maximum fan load.......................................................................................3 

A

mps

Incandescent maximum..........................................................................500 

W

atts

Fluorescent maximum..................................................................................400VA

LED maximum.........................................................................................150 

W

atts

..............................................................................*minimum light load of 10 

W

atts

Light and Fan Time Delay......................................15s, 

10

 mins, 

20 

mins, 30 mins

Humidity range..................................................................................45%-80% RH

PIR coverage.............................................................................................600sq.ft 

SPECIFICATIONS

 

DESCRIPTION

 

The DWHOS is a 3Amp, single pole Humidity/PIR occupancy sensor switch. This 

Sensor helps conserve energy and automate the light and fan in which it is 

connected. When the humidity sensor detects excess humidity in a room it 

automatically turns on the ventilation fan. The sensor continues to monitor the air 

and automatically turns the fan off when the humidity level drops below its preset 

level. Combines both technologies to reduce energy usage by operating the light 

or the fan only when needed.

COVERAGE

 

Figure 3

1.

2.

How to change the color cover/ push button.

The  switch  comes  with  the  top  cover  attached.  Remove  the  wall  plate

  if 

necessary

,  then the cover may be changed as follow:

REMOVAL

Push down on the cover/ push 

button to release, then pull away 

from  main body.

REATTACH

Align the latch pins to the unit, 

push the cover/ button against 

the main body, then slide up until 

its locked into place

OPERATI

NG INSTRUCTIONS

Single Pole

Wiring Diagram

The DWHOS features 

two

 adjustable operation modes for customized control to 

suit the specific ventilation

 and 

light

ing

 needs of the room. These modes are as 

follows; 

Occupancy with 

Automatic Humidity

 and Vacancy with Automatic 

Humidity.

The count-down timer can also be adjusted to set the minimum "ON" time for the 

lights at 

10

 minutes, 

20

 minutes, or 30 minutes.

  The fan will automatically turn on 

depend on the preset humidity.  

Once the Timer has been set, the switch will 

automatically turn the lights off when the selected time has expired. However the 

fan will continue to operate if the sensor detects excess humidity. 

The Fan will 

Automatically turn off after the humidity level is reached.  

The sensor switch is equipped with adjustable humidity level

s

. The humidity 

sensor can be adjusted 

to low

, medium, or 

high 

level.

When the PIR sensor detects movement the light button's green LED indicator will 

be flashing.  The fan's LED will turn red when the sensor detects excess humidity 

in a room; otherwise, it will always stay lit in white.

Press and hold both light and fan buttons for 10 seconds, the green LED indicator 

will come on solid.  This setting allows users to switch back and forth between 

Occupancy and Vacancy Mode.

Occupancy Mode*

 - Auto On/Automatic Off Lights. Auto On/

Automatic Off Fan base on preset humidity level.

o

Light: Auto On, Auto Off.

 The Light will automatically turn ON by 

PIR sensor.  Auto OFF by Time Delay.
When manual button is used to turn ON, lights turn ON and then turn 
OFF by preset time delay.
When manual button is used to turn OFF before the preset timer 
expired, lights turn off completely. After 3 minutes, PIR preset timer 
will resets and lights turn ON if motion is detected.

o

Fan: Auto On, Auto Off. 

The Fan will turn ON automatically when 

preset humidity level is reached and automatically turn OFF when the 
humidity level drops below the preset.
If the humidity level is higher than preset then the fan will continue to 
run after a 5 minutes break.
When the manual button is used to turn ON, the fan will turn ON for 
20 minutes and automatically turn OFF.
When the manual button is used to turn OFF before the 20 minutes, 
the fan will turn OFF immediately and the humidity sensor will stop 
detecting.  Only when the manual button is used to turn ON again, 
after 20 minutes the humidity sensor will be operational again. 

Vacancy Mode

 

-

 Manual On/Automatic Off Lights.

 

Auto On

/

Automatic Off Fan base on preset humidity level

o

Light: Manual On, Auto Off. 

Manual button is used to turn the 

Lights ON and Lights turn OFF automatically after preset time delay.
If motion is detected (within 30 seconds) of the lights turning off, the 
Lights will remain ON 

Figure 

2

HOT

Black

White
Neutral

White
Neutral

Red

Light

Brown

Fan

Green

Ground

Blue

Line 2

HOT

Black

Line 1

HOT

Отзывы: