INDUSTRIAL HEAVY DUTY
NOT INTENDED FOR RETAIL TRADE
Chemical System:
Zinc-Manganese Dioxide (Zn/MnO
2
)
(No Added Mercury or Cadmium)
Designation:
ANSI-908CD, IEC-4R25X
Battery Voltage:
6 Volts
Operating Temp:
-18ºC to 55ºC (0ºF to 130ºF)
Average Weight:
589 grams (20.8 oz.)
Volume:
480 cubic centimeters (29.2 cubic inch)
Average Capacity:
11 Ah to 0.8 volts / cell
(Rated at 25k ohms continuous at 21ºC)
Cell:
Four No. 60 (size "F") in series
Terminals:
Coil Spring
Jacket:
Plastic
INTERNAL RESISTANCE VS. TEMPERATURE
The measurement is an approximation of the
battery's actual internal resistance. It is sensitive
to the loads and operator technique.
Schedule:
Background Load 600 ohms
Pulse Load 10 ohms
Pulse Duration 1 second
0ºC (32ºF)
-21ºC (-4ºF)
THIS BATTERY WILL PASS FREELY THROUGH A
CYLINDRICAL TUBE 82.6 DIAMETER x 101.6 LONG.
ENERGIZER NO. EV190
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
6V
45ºC (113ºF)
Temperature
21ºC (70ºF)
Industry Standard Dimensions in mm (inches)
Typical Ri (ohms)
10.0
0.7
0.9
1.0
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
CONSTANT RESISTANCE PERFORMANCE
Typical Service
1
10
100
1000
1
10
100
1000
Discharge Resistance, Ohms
Service, Hours
3.0
Cutoff Voltage
4.4
Cutoff Voltage
5.2
Cutoff Voltage
EVEREADY BATTERY CO.
Internet: www.energizer.com
1-800-383-7323 / USA
1-800-383-7323 / CANADA
CONSTANT CURRENT DISCHARGE
Typical Service
1
10
100
1000
1
10
100
1000
Discharge Current, mA
Service Hours
3.0
Cutoff Voltage
4.4
Cutoff Voltage
5.2
Cutoff Voltage
1-800-383-7323 / USA
1-800-383-7323 / CANADA
+ 44 (0) 208 920 2306 / EUROPE
Form No. EBC - 3234A
Page 1 of 2