background image

www.energizerpower.com

  Printed in China

WARNING:

This Unit employs Components that tend to produce arcs or sparks – To 

prevent fire or explosion, do not install in compartments containing 

batteries or flammable materials - SHOCK HAZARD. DO NOT OPEN.

Notice :

The output of this device is not sinusoidal. It has a total harmonic distortion 

of 30% percent and maximum single harmonic of 8 percent

Toll Free: 1 866.295.6775

Owner's Guide

EN548

CAUTION:

OUTPUT NON-SINUSOIDAL REFER TO MANUAL - Provided with integral 

protection against overloads. To prevent fire, do not cover or obstruct 

ventilation openings. Do not mount in Zero-Clearance compartment. 

Overheating may result.

©2016 

Energizer  Energizer

 and other marks, including graphics, are trademarks of 

Energizer

 and used 

under license by PowerBright. All other trademarks, brand names or product names are the property of 

their respective owners and are not affiliated with 

Energizer

 or Bright Manufacturing LLC.

 

4010229

Conforms to UL Std.458,

Cert. to CSA Std. C22.2 No 107.1

Содержание EN548

Страница 1: ...95 6775 Owner s Guide EN548 CAUTION OUTPUT NON SINUSOIDAL REFER TO MANUAL Provided with integral protection against overloads To prevent fire do not cover or obstruct ventilation openings Do not mount...

Страница 2: ...using your EN548 and if you require any assistance please contact our help desk www energizerpower com or toll free 1 866 295 6775 Misusing or incorrectly connecting the EN548 may damage the equipmen...

Страница 3: ...d acid batteries These batteries unlike sealed batteries vent explosive hydrogen gas which can be ignited by sparks from electrical connections Use cautionwheninsertingan AC plugintothe three prongACo...

Страница 4: ...his product without causing the vehicle fusing to open Information on the vehicle fuse rating is typically found in the vehicle operator s manual If a vehicle fuse opens repeatedly do not keep on repl...

Страница 5: ...Do not connect any AC load that has its neutral conductor connected to ground to the EN548 Battery chargers usedin hand power tools These chargers display a warning label stating that dangerous volta...

Страница 6: ...t expose the to water rain snow or spray Failure to follow these safety guidelines may cause personal injury and or damage to the EN548 It may also void your product warranty Overload protection with...

Страница 7: ...6 EN548 DC Connectors Cooling Fan Back ON OFF Power Button AC Outlets USB port 2 4 Amp Front 4 Inverter Features LED Light...

Страница 8: ...re not affected by a modified sine wave you may need to consult with the manufacturer of the device you wish to run prior to connection with inverter Through its AC outlet the is capable of powering m...

Страница 9: ...able port on the EN548 and connect to a 12V cigarette lighter receptacle 2 Plug the device you want to operate into the EN548 3 When the inverter is not in use unplug it from the 12V outlet to prevent...

Страница 10: ...and switch them on if necessary Operating Guidelines As the battery is used its voltage begins to fall When the EN548 senses that the voltage at its DC input has dropped to 10 5V the inverter automati...

Страница 11: ...ts down The RED FAULT light comes on Should a defective battery charging system cause the battery voltage to rise to dangerously high levels the EN548 automatically shuts down The RED FAULT light come...

Страница 12: ...an operating time of 4 to 5 hours or more can be expected CAUTION Although the EN548 incorporates protection against over voltage it may still be damaged if the input voltage exceeds 16 V When using...

Страница 13: ...antenna and cables Maximize TV signal strength by using a better antenna and use shielded antenna cable where possible Some inexpensive stereo systems and AM FM radios have inadequate internal power...

Страница 14: ...ery and replace if required Loose connections Check connections Possible cause Solution Standard average reading AC voltmeter used to measure output voltage resulting in an apparent reading 5 to 15 V...

Страница 15: ...charged Recharge battery Possible cause Solution Unplug inverter from DC socket and allow to cool for 15 minutes Remove objects covering unit Move the inverter to a cooler place Reduce load if continu...

Страница 16: ...Surge Capacity Peak Power 1000 W Rated Input DC V A 13VDC 45A Input Voltage Range 10 5 to 15 5 VDC Rated Frequency Hz 60 Hz 1 Rated Output AC V A 4 17A 105 125 Rates Output USB V A 4 2 4A max 9 6A iPa...

Страница 17: ...H 5 to 95 Cooling System Fan Cooling over temperature THD 35 Power Factor 0 65 Min Ripple Noise Peak to Peak 250mV Dimensions LxWxH inches 8 3 x 5 15 x 2 3 Assembled Weight LBS 1 98 All specifications...

Страница 18: ...ption repair or replace the defective product free of charge provided that you notify PowerBright of the product defect within the Warranty Period and provided that PowerBright through inspection esta...

Страница 19: ...return shipments outside of the contiguous United States and Canada How do you get service If your product requires troubleshooting or warranty service contact your dealer If you are unable to contact...

Страница 20: ...se in an unsuitable environment b the product if it has been subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum...

Страница 21: ...ential damages so the above limitation s or exclusion s may not apply to you This Limited Warranty gives you specific legal rights You may have other rights which may vary from state to state or provi...

Страница 22: ...they are unauthorized returned without an RMA number clearly marked on the outside of the shipping box if they are shipped collect or ifthey areshipped to the wrong location When you contact PowerBri...

Страница 23: ...Technology Inc clearly marked on the outside of the box A return address where the unit can be shipped Post Office Boxes are not acceptable A contact telephone number where you can be reached during...

Отзывы: