background image

 

 

 

www.energie.pt                                                                                                                       

 

1

 

Assembly and user manual 

Thermodynamic Solar System 
 

Solar Block ULTRA (CH) 
Solar Block ULTRA PLUS (CH+DHW) 

 

   
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

EN 

CENTRAL HEATING/

  

DOMESTIC HOT WATER 

 

Review: 2

 

Version: 0

 

Date: 04/03/2021

 

Directives: 
2014/35/UE 
2014/30/UE 

 

According European Certification 
EN 60335-1 
EN 60335-2-21 

Содержание SB 12 ULTRA

Страница 1: ...Thermodynamic Solar System Solar Block ULTRA CH Solar Block ULTRA PLUS CH DHW EN CENTRAL HEATING DOMESTIC HOT WATER Review 2 Version 0 Date 04 03 2021 Directives 2014 35 UE 2014 30 UE According Europe...

Страница 2: ...ASSEMBLYANDUSERMANUAL SOLAR BLOCK ULTRA 2 www energie pt Directivas 2006 95 CE...

Страница 3: ...r panel 8 3 5 2 Thermodynamic Solar Block 8 3 5 3 Unit storage 8 4 THERMODYNAMIC SOLAR BLOCK 9 4 1 Operation 9 4 2 Components 9 5 TECHNICAL SPECIFICATIONS 10 5 1 Solar Block 6 ULTRA 10 5 2 Solar block...

Страница 4: ...ection of the panels to the Solar Block 24 6 3 6 Leak test 24 6 3 7 Vacuum 25 6 3 8 Refrigerant load 25 7 ULTRA PLUS SOLAR BLOCK ACTIVATE DHW BACKUP RESISTANCE 26 8 ULTRA SOLAR BLOCK ACTIVATE DHW CONT...

Страница 5: ...product without any prior notice Our services are always at your disposal Feel free to call upon us 2 GENERALITY 2 1 Symbology The notes symbols shown can be found throughout the manual They are inte...

Страница 6: ...are reduced or by people without any experience or knowledge unless they have been given supervision or instructions about use of the appliance by someone responsible for its safety Children must be s...

Страница 7: ...ULTRA 115 SB 16 ULTRA 128 SB 32 ULTRA 135 SB 12 ULTRA PLUS 1880x752x1002 110x750x1000 230 SB 16 ULTRA PLUS 243 Table 1 Dimensions of the boxes pallets and respective weights 3 4 Transporting the unit...

Страница 8: ...is the responsibility of the installer to strengthen the panel affixation structure 3 5 2 Thermodynamic Solar Block The Block installation site must be carefully designed And before carrying out any...

Страница 9: ...nt fluid vapour of the panel raising the pressure and temperature thereof which is transmitted to the water circuit by way of a heat exchanger The heat exchanger is located inside the thermodynamic gr...

Страница 10: ...1 Evaporator Thermodynamic solar panel Number 6 Material Aluminum surfece m 9 6 Refrigerante Type R410A Min load Kg 1 9 Hydraulic circuit Nominal flow m3 h 1 7 N of pumps 1 Typology EC Max power cons...

Страница 11: ...r Thermodynamic solar panel Number 12 Material Aluminum surfece m 19 2 Refrigerante Type R410A Min load Kg 3 5 Hydraulic circuit Nominal flow m3 h 1 6 N of pumps 1 Typology EC Max power consuption W 6...

Страница 12: ...Thermodynamic solar panel Number 16 Material Aluminum surfece m 25 6 Refrigerante Type R410A Min load Kg 4 5 Hydraulic circuit Nominal flow m3 h 2 8 N of pumps 1 Typology EC Max power consuption W 60...

Страница 13: ...vaporator Thermodynamic solar panel Number 32 Material Aluminum Surface m 51 2 Refrigerante Type R410A Min load Kg 7 Hydraulic circuit Nominal flow m3 h 6 5 N of pumps 1 Typology EC Max power consupti...

Страница 14: ...ify the operationality of the equipment the installing technician must have at its disposal Multimeter Appliance for measuring temperature EVD display 6 2 Thermodynamic Solar Panel 6 2 1 Panel orienta...

Страница 15: ...Solar block 16 20m Solar block 32 30m For Installations with a distance greater than those indicated must contact the Technical Dept 6 2 4 Unevenness Under normal circunstances the total maximum grad...

Страница 16: ...panels on the side opposite the connections they should preferably not be completely stuck together preferably 20mm 6 2 6 Direction of the panels The direction of the panels is defined by the outlets...

Страница 17: ...cordance with the representation indicated above with a red cross 6 2 7 Solar panels layout The relative position of the panels depends on the system to be installed the availability of the installati...

Страница 18: ...hey must have a sturdy structure in line with the circumstances of the site Each panel must be secured at 6 points as a minimum The image below illustrates an example of the fixation used The fixation...

Страница 19: ...e placed before the installation of the panels for the sake of convenience obstruction passage of distribution tubes behind the panels Only remove the tube protection cover at the time of connection t...

Страница 20: ...connections at the collectors to be as simple as possible respecting the instructions in the event of any unevenness It is essential for the copper tubes used to be refrigerant type CUDHP according t...

Страница 21: ...gards the rear panel of the equipment and the installation site the installer must respect a minimum distance of 150mm to allow easy access to the hydraulic and refrigerant connections The installatio...

Страница 22: ...www energie pt 6 3 3 Connections SB ULTRA and SB ULTRA PLUS The back of the Thermodynamic Block has the various connections in accordance with the designation set out below A B D A C E F E F B G G BS...

Страница 23: ...e now the following types of piping must be placed Liquid Outward to panels Aspiration Return from panels Before making the aforementioned connections it is best to carry out the connections of the pa...

Страница 24: ...and the whole refrigerant fluid loading process 6 3 5 Inlet Outlet connection of the panels to the Solar Block The ULTRA ULTRA PLUS Solar Block leaves the factory with nitrogen loading 30bar Take car...

Страница 25: ...p are closed The vacuum manometer must always have the same display after stopping the pump thereby ensuring that the installation maintains the vacuum After vacuuming do not remove the hoses until th...

Страница 26: ...of the equipment to the socket 230V The resistance has an integrated thermostat that is regulated to heat the water up to 55 C 8 ULTRA SOLAR BLOCK ACTIVATE DHW CONTROL The ULTRA Solar Block is set by...

Страница 27: ...lustrates the type of filter to be used When the circuit is properly connected fill the hydraulic circuit and as this operation is being undertaken you must purge all the circuits ensuring that you el...

Страница 28: ...K ULTRA 28 www energie pt 9 1 Hydraulic connection BS ULTRA Central Heating 9 2 Hydraulic connection BS ULTRA DHW It is recommended to install a thermostatic mixing valve in the DHW circuit according...

Страница 29: ...ASSEMBLYANDUSERMANUAL SOLAR BLOCK ULTRA www energie pt 29 9 3 Hydraulic connection BS ULTRA CH DHW CH...

Страница 30: ...valve in the DHW circuit according to the following diagram These hydraulic drawings just show the core parts and main principle of the application DHW output Shut off Valve Thermostatic Mixing Valve...

Страница 31: ...the table below The maximum admissible losses for a cable of no more than 5 metres have already been considered in the calculations Single phase cable section mm2 Three phase cable section mm2 SB 6 UL...

Страница 32: ...board The terminal shown in the figure below has six buttons with the following functions Alarm Alarm Shows the list of active alarms and allows access to the alarm history Menu Menu Allows you to ent...

Страница 33: ...ve circulating pump 4 Unit status 1 OFF Equipment on OFF 2 ON All functions are active The unit adjusts the parameters according to the active operating mode 3 ENERGY SAVE All functions are active The...

Страница 34: ...cturer Each user sees only the parameters and menu options available for their respective access level Main menu function tree A Unit state ON OFF AUTO ENERGY SAVE DHW only HEATING DHW B Setpoint Nomi...

Страница 35: ...ched on in any other mode If the digital input is active ON status the equipment can be switched on or off through the console 2 The selected options can be HEATING DHW central heating domestic hot wa...

Страница 36: ...the equipment is only effectively assumed if the equipment is in auto mode Note The anti ice protection is guaranteed on OFF mode D Input Output In the main menu D you can check the physical status of...

Страница 37: ...one menu that shows the equipment in the pLAN network Each device is followed by its network address for example uPC board 1 G Service The main menu G is divided into two parts the first a b c without...

Страница 38: ...f the storage water heater circuit management Check probe ALA09 Compressor discharge temperature off or damaged Automatic Equipment on safe mode OFF Check probe ALA10 Suction temperature probe off or...

Страница 39: ...n cable ALD04 Low overheating Manual Equipment on safe mode OFF Check if there is no obstruction in the air circulation in the external unit ALD05 Low suction temperature Manual Equipment on safe mode...

Страница 40: ...BLYANDUSERMANUAL SOLAR BLOCK ULTRA 40 www energie pt 11 Param default 12 DC bus ripple 13 Data comms fault 14 Drive thermistor 15 Autotune fault 16 Drive disabled 17 Motor phase 18 Fan fault 19 Speed...

Страница 41: ...manufacturer A repair under the warranty is not reason for an extension of its term Warranty Exclusions The warranty ceases to be effective when the apparatus is no longer connected used or assembled...

Страница 42: ...rned after more than 15 days have passed since the purchase date of the apparatus ATTENTION Technical assistance costs even within the warranty period shall be supported by the customer Km and assista...

Страница 43: ...ASSEMBLYANDUSERMANUAL SOLAR BLOCK ULTRA www energie pt 43 NOTE...