NOTE
After the charge termination, while the battery remains connected, the final values of
[Voltage/cell], [Time] and [Capacity charged] remain stored in memory.
If the red STOP pushbutton is pressed, the display will show these values in sequence.
If the charge has been terminated manually, equalization and
maintenance functions are automatically disabled.
EQUALIZATION
CAUTION!
NEVER disconnect the battery while it’s being charged.
Disconnecting the battery while it’s being charged is hazardous
for the user and voids the charger warranty.
The EQUALIZATION function is useful to keep all the cells of the battery at the same voltage level, even
after years of continuous work . When a battery is charged/discharged everyday, it’s suggested to equalize it
weekly .
The charger, after a normally completed charge cycle, will add 4 extra charges of 30 minutes, with 15 hours
interval between each charge .
During the interval between each equalization charge, the display will show the scrolling message: “End”:
When the equalization chargers are in progress, the display will show the message“F1”, followed by the
current value: