background image

[0203072TSS] TSS-D Battery Chargers r1

User's Manual

 

BATTERY TERMINALS – Do not touch battery terminals while equipment is operating.

SERVICE AND MAINTENANCE – Shut OFF all power at the disconnect switch or line breaker
BEFORE inspecting, adjusting, or servicing the equipment. Lock switch OPEN (or remove line
fuses) so that the power cannot be turned ON accidentally.
Disconnect power to equipment if it is to be left unattended or out of service. Disconnect
battery from charger. Keep inside parts clean and dry. Dirt and/or moisture can cause
insulation failure. This failure can result in high voltage at the charger output.

BURN AND BODILY INJURY PREVENTION

The battery produces very high currents when short circuited, and will burn the skin severely
if in contact with any metal conductor that is carrying this current.
Do not permit rings on fingers to come in contact with battery terminals or the cell connectors
on top of the battery. Battery acid is very corrosive. Alwais wear correct eye and body
protection when near batteries.

FIRE AND EXPLOSION PREVENTION

When batteries are being recharged, they generate hydrogen gas that is explosive in certain
concentrations in air (the flammability or explosive limits are 4.1% to 72% hydrogen in air).
The spark-retarding vents help slow the rate of release of hydrogen, but the escaping
hydrogen may form an explosive atmosphere around the battery if ventilation is poor.
The ventilation system should be designed to provide an adequate amount of fresh air for the
number of batteries being charged. This is essential to prevent an explosion. 
Always keep sparks, flames, burning cigarettes, and other sources of ignition away from the
battery recharging area. Do not break "live" circuits at the terminals of batteries. Do not lay
tools or anything that is metallic on top of any battery.

ARCING AND BURNING OF CONNECTOR

To prevent arcing and burning of the connector contacts, be sure the charger is OFF before
connecting or disconnecting the battery. The ammeter should NOT indicate current flow.

MEDICAL AND FIRST AID TREATMENT

First aid facilities and a qualified first aid person should be available for each shift for
immediate treatment of electrical shock victims.
EMERGENCY FIRST AID: Call phisician and ambulance immediately and use First Aid
techniques recommended by the American Red Cross.

DANGER: ELECTRICAL SHOCK CAN BE FATAL.
If person is unconscious and electric shock is suspected, do not touch person if he or she is
in contact with charging equipment, battery, charging leads, or other live electrical parts.
Disconnect power at wall switch and then use First Aid.
Dry wood, wooden broom, and other insulating material can be used to move cables, if
necessary, away from person.
IF BREATHING IS DIFFICULT, give oxygen.
IF NOT BREATHING, BEGIN ARTIFICIAL BREATHING, such as mouth-to-mouth.
IF PULSE IS ABSENT, BEGIN ARTIFICIAL CIRCULATION, such as external heart massage.

In case of acid in the eyes, flush very well with clean water and obtain professional medical
attention immediately.

__________________________________________________________________________________________________________________________________________________

Page 3/19

Содержание TSS-D

Страница 1: ...er s Manual TSS D Battery Chargers USER S MANUAL V1 0 Jan 2017 www energicplus com _____________________________________________________________________________________________________________________...

Страница 2: ...ating gloves when dampness or sweat cannot be avoided Keep clothing dry INSTALLATION AND GROUNDING A power disconnect switch must be located at the equipment Check the data label for voltage and phase...

Страница 3: ...resh air for the number of batteries being charged This is essential to prevent an explosion Always keep sparks flames burning cigarettes and other sources of ignition away from the battery recharging...

Страница 4: ...er to charge the battery cells The microprocessor controlled electronic card is used to monitor the state of the charge and automatically turn the charger off when the battery is fully charged The cha...

Страница 5: ...orted on the data label is available from your power supply and verify that the unit s operating voltage is correct Allow adequate air circulation to prevent internal heat buildup Don t place the unit...

Страница 6: ...attery Chargers r1 User s Manual SIZE DIMENSION INTERNAL PARTS _________________________________________________________________________________________________________________________________________...

Страница 7: ...sured value Example 1 if the measured voltage is 210 VAC the transformer should be connected to the tap that corresponds to 208 VAC Example 2 if the measured voltage is 235 VAC the transformer should...

Страница 8: ...emove the metal bars and position them in the correct configuration Fix the nuts carefully Mount the plastic protection over the BVS Close the cabinet Metal bars in position 208 240 Vac Metal bars in...

Страница 9: ...3 2 1 VOLTAGE 208V 220V 240V MODELS WITH INPUT VOLTAGE 1x208 240 480V POSITION 3 2 1 BVS AT 240 Vac 208V 225V 240V BVS AT 480 Vac 452V 480V 508V _______________________________________________________...

Страница 10: ...ng with any applicable national or local code Check that the charger is disconnected from AC input and battery Open the cabinet Mount the input cable and connect the four power conductors three phase...

Страница 11: ...and in accordance with any applicable national or local norm BUTTON START STOP and BUTTON EQ are INCLUDED OUTSIDE THE FRONTAL LABEL BUT INSIDE THE FRONTAL PANEL _______________________________________...

Страница 12: ...he flashing error message Voltage High If the battery voltage is between the minimum and maximum thresholds the charger will turn on automatically after 5 seconds If during the charge the battery volt...

Страница 13: ...played To display the time the charger uses this format HOURS MINUTE DECADES h Examples Time of charge 3h 30minutes Displayed 3 3h Time of charge 7h 50minutes Displayed 7 5h The charge current follows...

Страница 14: ...a black out of the AC input occurs the charger saves automatically all the relevant information about the state of the charge While the input power is absent the message Black Out is displayed When th...

Страница 15: ...___________________________________________________________________________________________________________________________ Page 15 19 NOTE After the charge termination while the battery remains conne...

Страница 16: ...isconnect and re connect the battery DAILY EQUALIZE The DAILY EQUALIZE function will extend all the charge cycles by 4 hours and it s suitable to recover batteries that are lightly sulphated It can be...

Страница 17: ...ompleted normally the charger will add 5 short additional charge cycles of 30 minutes with 14 hours and 30 minutes interval between each charge During the time interval between each equalization charg...

Страница 18: ...minimum threshold the charger will give a refresh charge to pull up the voltage to a programmed maximum threshold and the display will show the message F2 _____________________________________________...

Страница 19: ...ut settings to lower voltage 2 One AC phase is absent Check AC input voltage on each phase 3 One or more diodes blown Replace rectifier 4 Bad contactor Replace contactor Charger smells hot 1 Bad locat...