background image

1

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

Enerco Technical Products, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 · 866-447-2194

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

UNVENTED LP-GAS FIRED ROOM HEATER

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

Model #

HSSVFRD10LPT

HSSVFBF10LPT

READ INSTRUCTIONS CAREFULLY:

 YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and 

follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has 
not read these instructions to assemble, light, adjust or operate the heater.

 WARNING: If the information in this manual is not followed exactly, a fire or explosion may 

result causing property damage, personal injury, or loss of life. 

 

-

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 
other appliance.

 

-

WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• 

If you cannot reach your gas supplier, call the fire department.

 

-

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. 
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for 
Combustion and Ventilation section on page 4 of this manual. 

This appliance may be installed in an aftermarket permanently manufactured (mobile) home, 
where not prohibited by local codes. 
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is 
not convertible for use with any other gas.

Blue Flame Heaters

HSSVFBF10LPT

Plaque Heaters 

HSSVFRD10LPT

Содержание F156001

Страница 1: ...vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building...

Страница 2: ...bustion of such fuel can expose you to chemicals including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go...

Страница 3: ...air for proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before...

Страница 4: ...ll not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel...

Страница 5: ...Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework worksheet adding the space of the adjoining unconfined space Th...

Страница 6: ...Figure 4 For convenience and efficiency install the heater Where there is easy access for operation inspection and service In the coldest part of the room CAUTION If you install the heater in a home...

Страница 7: ...ill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting b...

Страница 8: ...l require you to use a 3 8 NPT street elbow to make gas connection CAUTION Never connect heater directly to the Propane supply This heater requires an external regulator not included Install the exter...

Страница 9: ...relieve pressure in supply piping system 7 Reconnect heater and equipment shutoff valve to gas supply 8 Reconnected fittings must be checked for leaks in next section Low Pressure Test Pressure Equal...

Страница 10: ...rn Once knob is in PILOT IGN depress for five 5 seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This w...

Страница 11: ...all soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We also recommend that you keep the burn...

Страница 12: ...by any metal or tubing Keep igniter cable dry Broken igniter cable Replace igniter cable Bad Piezo igniter Replace control valve Low Battery Replace battery When ignitor button is pressed in there is...

Страница 13: ...rty or partially clogged burner orifice Clean burner orifice see Cleaning and Maintenance on page 1 1 or replace burner orifice White powder residue forming within burner box or on adjacent walls or f...

Страница 14: ...oor Mounting Feet Beige 1 80214 Floor Mounting Feet White 1 ITEM P N PART DESCRIPTION QTY 12 NA Regulator Connection 1 13 80036 Wall Mounting Bracket 1 14 80052 Back Panel Beige 1 80177 Back Panel Whi...

Страница 15: ...Floor Mounting Feet White 1 9 NA Regulator Connection 1 ITEM P N PART DESCRIPTION QTY 10 80036 Wall Mounting Bracket 1 1 1 80052 Back Panel Beige 1 80177 Back Panel White 1 12 80010 Thermostat Valve...

Страница 16: ...s may be purchased at any Heatstar Products local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 WWW HEATSTARBYENERCO COM Our office hours are 8...

Отзывы: