background image

e n d u r a

®

ENDURA

®

GREASE INTERCEPTOR

RECESS EXTENSION
RISER INSTALLATION  P/N 3935AX6, 3920AX6

Components

Equipment Required

3 - 1/2" Sch 40 pipe

Silicone Sealant

Level

3 - 1/2" Sch 40 couplings

Hammer

Screwdriver

2 - L Shaped extension components

Pliers

Saw

11 - 1 1/4" screws

Nail Punch

Pencil

Preparing the Endura Tank to Accommodate the Extension

Disengage the Quick Connect latches and remove the lid from the tank.

With a hammer and a punch, 
disengage the dowel pin from the tank.
Using a pair of pliers, remove the
dowel pin. Repeat this procedure for all
of the pins housed in the tank.

1

Insert the tank into the excavated hole
and locate the pipe connections to the
desired height.

2

Level the tank into its final position and
secure to the piping.

3

Отзывы: